Model Image GTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1;IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C;
Information
Model NumberGTM91120-30VV-T2
DescriptionGTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1;IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C;
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000C2VkdEAF
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000C2VkdEAF
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000C2VkdEAF
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000C2VkdEAF
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000C2VkdEAF
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000C2VkdEAF
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination / Stecker-/Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical/ICT/ITE/Household use Power Supply / Medical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress ProtectionIP40 (cord), IP52(R-blades)
Size (mm)(L)101.77x(W)47.47x(H)36.7
Enclosure

User-added image




User-added image



            Units shipped without an installed input plug have a "desktop insert" installed.
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM91120-2007.5-2.5-T2* 5420
GTM91120-1007.5-2.5-T2* 5210
GTM91120-3007.5-1.5-T2* 63.7522.5
GTM91120-3007.5-T2* 7.5322.5
GTM91120-3010.5-1.5-T2* 92.7724.93
GTM91120-2510.5-1.5-T2* 92.825.2
GTM91120-3010.5-1.4-T2* 9.13.330.03
GTM91120-3010.5-1.2-T2* 9.33.229.76
GTM91120-2510.5-0.9-T2* 9.62.624.96
GTM91120-3014.5-2.5-T2* 122.530
GTM91120-1214.5-2.5-T2* 12112
GTM91120-1714.5-1.5-T2* 131.316.9
GTM91120-3019.5-4.5-T2* 15230
GTM91120-3019.5-1.5-T2* 181.6629.88
GTM91120-3019.5-0.5-T2* 191.5729.83
GTM91120-3024-T2* 241.2530
GTM91120-2736-9.0-T2* 27127
GTM91120-3036-6.0-T2* 30130
GTM91120-3036-T2* 360.8329.88
GTM91120-3048-T2* 480.62530
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output Regulation: +/- 5% measured at the output connector
4. Line Voltage Regulation: +/- 2% typical measured at full load
5. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector
Optional low ripple option available (RFP4579)
6. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
7. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
8. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
9. Inrush Current: 60A maximum cold start @ 240Vac input
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -40°C to 80°C “24h recovery time at room temperature”.
5. Cooling: Convection
6. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: (L)101.73 x (W)46.47 x (H)38.2 +/-1.0 mm
3. Markings: Label and/or Pad Printed and/or Molded in the case
4. LED: Standard GREEN color to indicate power out
Derating CurveUser-added image
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)142*62*60
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)37.5
Label Height (mm)33.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C8 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
1. Class II model NEMA 1-15P AC power plug with 2 prongs, R-NA-2(R) 
2. Australian AS 3112 configuration: SAA 2 pins Class II, R-SAA-2(R) 
3. UK BS 1363 configuration: UK 2 pins (dummy Ground) Class II, R-UK-2(R) 
4. European CEE 7/16 configuration: Europlug 2 PINS, Class II, R-EU-2(R) 
5. China GB 2099 configuration: 2 blades, Class II; CN P/N:R-CN-2(R)
6. Desktop Insert
Kits
05. R-KIT-2(R): 1,2,3,4 above
06. R-KIT-2-INTL(R): 2,3,4 above

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
 
Part NumberCountryPlugConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703B(R)India (Type M)BS 546IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
 User-added imageCCC to GB4943. 1-2011; GB9254-2008; GB17625. 1-2012 with Tropical and Altitude up to 5000 m approval.

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageAAMI ES60601-1:2005 +A1 - Medical Electrical Equipment - Part 1: General Requirements CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1 IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imagecRUus UL Recognized Component E172861 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added image
 
UL60950-1, cULus to UL 60950-1, 1st Edition, 2007-10-31 and CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07
User-added image
User-added image  Certification # TC RU AR46.B.69004 Custom Union of Russia, Belarus and Kazakhstan
User-added image
FCC PART 15 CLASS B
User-added image
 
Fuse 60335 T3.15A 250VAC Up to 36 volts
Ta:40°CIEC 61558-1 Maximum Ambient Temperature, Max 40°C
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP40Ingress Protection: ?IP40 to IEC60529:2001 Protection against granular foreign bodies (with I/P cord)
IP52Ingress Protection: ?IP52 to IEC60529:2001 Protected against dust - limited ingress (no harmful deposit) and Protected against direct sprays up to 15 degrees from the vertical (with R-Blades)
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50314327, to J60950-1(H26) , J55022(H22),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD50473430 , to J62368-1(H30) , J55032(H29),J3000(H25)[DC15? 30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30? 60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
User-added image
 
RCM certificate SAA-161679-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
IEC 60601-1:2005+A1 EN 60601-1:2006+A1:2013+A12:2014 IEC 60601-1-11:2015 EN 60601-1-11:2015
User-added imageSemko S-Mark-Cert- EN60950-1
User-added image
Serial Number Information
User-added image
IEC/EN60335-1
SIQ IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 volts
User-added image
IEC/EN61558-1
EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009
User-added imageTransformer Symbol IEC 61558-1 SMPS Short-Circuit –Proof Safety Isolating Transformer
User-added imageTransformer Symbol IEC 61558-1 SMPS Switch Mode Power supply
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
8689265.04.02Pin magnetic connector -1
1681395.04.0Female Barrel Right Angle, 5.5*2.1*11mm with internal Spring Clip and Locking Notch or Equal
1794095.03.0"Z" series Universal Connector Jack with retention lock; Connector is not included and must be ordered separately. see Listing: http://en.globtek.com/z00-socket-configs.php
1784125.04.0Female Barrel Right Angle, 5.5*2.1*11mm with internal Spring Clip and Locking Notch or Equal
1920535.04.0AMP Mini Universal Mate-n-Lock, 794188-1, or equal with AMP socket 794223-1 (Qty 4) or equal
2672675.04.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
1682095.02.0USB type B or Equal
1681585.04.0Female Barrel Right Angle 4.0*1.7*9.5mm No internal Spring Clip nor Locking Notch or Equal
1681295.04.0Female Barrel 5.5*2.5*11mm, Right Angle w/ Spring Clip & Locking Notch or Equal
2143055.04.0Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
1672305.04.0Female Barrel 5.5*2.1*12mm No internal Spring Clip nor Locking Notch or Equal
1646745.04.0Female Barrel 3.5*1.35*9.5mm, Locking with Spring-loaded or Equal
16807835.04.02Pin Magnetic Connector, MALE, P/N 806-1810conadapt016
1465375.04.0Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
1465365.04.0Female Barrel 5.5 * 2.5 * 9mm No internal Spring Clip nor Locking Notch or Equal
1279925.04.0Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
2624775.04.0Micro-B USB 5 Pin Type "B" or Equal
1795535.04.0Female Barrel 3.5*1.35*9.5mm, Locking with Spring-loaded or Equal
2579635.04.0Female Barrel Right Angle, 5.5*2.1*11mm with NO internal Spring Clip NOR Locking Notch or Equal
10441465.02.0Female Barrel 3.5*1.35*11.5mm, Locking with Spring-loaded or Equal
1894136.01.5Female Barrel Right Angle, 5.5*2.1*12mm No internal Spring Clip nor Locking Notch or Equal
1811806.01.0Female Barrel 5.5 * 2.5 * 9mm No internal Spring Clip nor Locking Notch or Equal
1358167.53.0Female Barrel 5.5*2.5*9.5mm No internal Spring Clip nor Locking Notch or Equal
1800949.02.77Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
1916369.02.8Female Barrel 5.5*2.5*9.5mm No internal Spring Clip nor Locking Notch or Equal
1960299.03.3Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
1811819.01.0Female Barrel 5.5 * 2.5 * 9mm No internal Spring Clip nor Locking Notch or Equal
1999429.02.8Female Barrel 5.5*2.5*9.5mm No internal Spring Clip nor Locking Notch or Equal
1999439.02.8RJ11 Plug, 6 Pin or Equal
1784119.02.77Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
1920579.13.3Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
1964999.13.3Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
1807469.13.3Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
1864459.13.3Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
1782079.13.3Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
2011929.33.2Female Barrel 5.5*2.1*14mm No internal Spring Clip nor Locking Notch or Equal
1681819.62.6Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
61858212.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
61808112.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
18428412.02.5Cable Socket, 3-pole, Female, Binder P/N 99 3400 00 03 or equivalent
37601412.02.5Female Barrel, Right Angle 3.5 * 1.35 * 10 mm No internal Spring Clip nor Locking Notch or Equal
17828312.02.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
19510112.02.5Female Barrel 5.5*3.3*9.5mm w/1.0 mm Pin or Equal
19644512.02.5Female Barrel 5.5*3.3*9.5mm w/1.0 mm Pin or Equal
17941012.02.5"Z" series Universal Connector Jack with retention lock; Connector is not included and must be ordered separately. see Listing: http://en.globtek.com/z00-socket-configs.php
18028412.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
18157812.02.5Female Barrel 3.5*1.35*9.5mm, without Locking Notch nor Spring Clip or Equal
18191612.02.5Female Barrel 3.5*1.35*9.5mm, without Locking Notch nor Spring Clip or Equal
18253012.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
18304112.02.5Cable Socket, 3-pole, Female, Binder P/N 99 3400 00 03 or equivalent
32390212.02.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
18419212.02.5Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
26456412.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
26425512.02.5Female Barrel 5.5*2.5*10.0mm, Right Angle with internal Spring Clip & Locking Notch or Equal
26248912.02.5Waterproof IP68 Molded Female Plug, 2 sockets, 3.0mm Pitch, Equivalent to KCC sk2/2
24960212.02.5Female Barrel Right Angle, 5.5*2.1*11mm with NO internal Spring Clip NOR Locking Notch or Equal
22772812.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
21461512.02.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
19954812.02.5Female Barrel 5.5*2.5*9.5mm, Right Angle without internal Spring Clip & Locking Notch or Equal
21511412.02.5Stripped 30 +/-5mm; Tinned 9 +/- 2mm or Equal
18716612.02.5Housing: JST XHP-2, Contacts: JST SXH-001T-P0.6, No Equivalent
18669812.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17809112.02.56.4*4.0mm
17787412.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17713312.02.5Socket for interchangeable o/p connectors
17497212.02.5RP34L-5PA-3SC(71)
17496812.02.5Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
16869712.02.5Female Plug 9.2*8.3*13mm
156683512.02.5Female Barrel Right Angle, 5.5*2.1*11mm with NO internal Spring Clip NOR Locking Notch or Equal
12914312.02.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
17516612.02.5Female Barrel Right Angle, 5.5*2.1*11mm with internal Spring Clip and Locking Notch or Equal
12914212.02.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
10240212.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
61860712.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
23316013.01.3Stripped 31 +/- 2mm; Tinned 6 +/- 2mm or Equal
18633513.01.3Female Barrel 5.5*2.5*9.5mm, Right Angle with internal Spring Clip & Locking Notch or Equal
19835813.01.3Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
18648413.01.3Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
17716913.82.17Female Barrel 5.5*2.5*11mm, Right Angle without internal Spring Clip & Locking Notch or Equal
19093815.02.05-Pin Circular Connector, Binder P/N 99-9114-00-05 NO EQUIVALENT!
22408015.02.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
22628415.02.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
17696815.02.0Female Barrel 5.5 * 2.5 * 11mm with no internal Spring Clip and Locking Notch or Equal
16343015.02.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
21807915.02.0Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17713715.02.0Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
18171815.02.0Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
19927916.01.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
17950818.01.7Female Barrel 5.5*2.5*12mm, Right Angle No internal Spring Clip nor Locking Notch or Equal
19166518.01.66Female Barrel 6.5 x 4.4 x 1.37 x 14mm Straight or Equal
21486919.01.57Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
16972624.01.3Female Barrel 5.5*2.5*13.8mm w/6.5mm Thumb Screw, 760K or Equal mates with PC712A, 712A
18045124.01.25Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
91965424.01.3Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
14654024.01.25Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
17101624.01.3Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17102124.01.25Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17132724.01.25Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17512524.01.3Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17588024.01.25Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
17941124.01.25"Z" series Universal Connector Jack with retention lock; Connector is not included and must be ordered separately. see Listing: http://en.globtek.com/z00-socket-configs.php
18647324.01.25Female Barrel Right Angle, 5.5*2.1*11mm with NO internal Spring Clip NOR Locking Notch or Equal
19972124.01.32 Pin FX9
22489224.01.3Stripped 20+/-2mm, Tinned 5+/-2mm with Black Thermal Contracting Sleeve or Equal
117452224.01.25Female Barrel 5.5*2.1*11mm No internal Spring Clip nor Locking Notch or Equal
26162124.01.25Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
27188724.01.330 ±2mm Strip, 4 ± 1mm Tin or Equal
25281727.01.0Female Barrel 5.5*2.1*9.5mm No internal Spring Clip nor Locking Notch or Equal
16325830.01.0Female Barrel 5.5*2.1*9.5mm No internal Spring Clip nor Locking Notch or Equal
18203030.01.0Female Barrel 5.5*2.1*9.5mm No internal Spring Clip nor Locking Notch or Equal
16697530.01.0Female Barrel 5.5*2.1*9.5mm No internal Spring Clip nor Locking Notch or Equal
18037744.50.67Female Barrel 5.5*2.5*12mm No internal Spring Clip nor Locking Notch or Equal
18089848.00.625Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
19771448.00.6252 x RJ-45 Jacks mounted in 94V-0 enclosure per IEEE 802.3af configuration
News Releases
TitleWeb Link
CB Certificate IEC 60335-1:2010 (5th ed.) CB report IEC 60335-1:2010 (5th Ed.) and EN 60335- 1:2012.

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist ein Steckernetzteil/Tischnetzteil?

Stecker-/Tischnetzteile werden auch als AC-Adapter oder AC/DC-Wandler bezeichnet und sind eine Art externes Netzteil. Diese Geräte können mit einem standardmäßigen IEC 60320-Netzkabel oder mit dem eigenen Eingangssteckersystem als Steckernetzteile verwendet werden und ohne Kabel direkt in die Steckdose gesteckt werden. Einige Elektrogeräte benötigen Strom, es fehlen jedoch die internen Komponenten, um die erforderliche Spannung und Leistung aus dem Stromnetz beziehen zu können. Hier wird ein Netzteil verwendet, das den Wechselstrom in Gleichspannung umwandelt.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?