World map Deutsch

GT-91128LIXCEL Wall Plug-in ICT/ITE Power Supply Datasheet

Request Information Download PDF Configure Output Connector
GT-91128LIXCEL Image
Model Image GT-91128LIXCEL, ICT/ITE Power Supply, Wall Plug-in, Li-Ion Battery Charger, , Input Rating: 100-240V~, 50-60 Hz, NEMA 1-15P, North America Blades, Class II 2 Conductors, Output Rating: 4.2 Watts, Power rating with convection cooling (W) , 4.2V in 0.1V increments, Approvals: ETL; CB 60335;
Information
Model NumberGT-91128LIXCEL
DescriptionGT-91128LIXCEL, ICT/ITE Power Supply, Wall Plug-in, Li-Ion Battery Charger, , Input Rating: 100-240V~, 50-60 Hz, NEMA 1-15P, North America Blades, Class II 2 Conductors, Output Rating: 4.2 Watts, Power rating with convection cooling (W) , 4.2V in 0.1V increments, Approvals: ETL; CB 60335;
Agency Documents
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for MedicalContact GlobTek for more information
UKCA-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MmNnVEAV
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MmNnVEAV
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in / Steckergerät
TechnologyLi-Ion Battery Charger
CategoryICT/ITE Power Supply / ICT/ITE Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)2A
Max Output Power Rating (W)4.2
Output Voltage Range (V)4.2
EfficiencyN/A
Ingress ProtectionIndoor Use
Size (mm)60*65*26
EnclosureUser-added image
 
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GT-91128LI1CEL* 4.214.2
GT-91128LI1CEL* 8.41.210.08
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS per each channel:
Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
Input Current: < 2A RMS Max
01. Charging Voltage: 1 cell: 4.2Vdc, +/-1% Maximum; 2 cell: 8.4Vdc, +/-1% Maximum; 3 cell: 12.6Vdc, +/-1% Maximum
02. Pre-Charge Current: 10% of bulk charge current
03. Bulk Charge Current: ±10%
04. Pre-Charge to Bulk Charge Battery
05. Transition Voltage: 1 cell: 2.86Vdc to 3.15Vdc, 2 cell: 5.72Vdc to 6.30Vdc; 3 cell: 8.58Vdc to 9.45Vdc Charger will be in pre-charge mode when the battery voltage is below the transition voltage.
06. Battery Charging Ambient Temperature: 0°C to 35°C
07. Charge Termination Current: 10% of bulk charge current
08. Back-Up Charge Termination: Timer set 2 to 3 hours after the expected full charge time
09. Charger will terminate charging when timer expired
10. Battery Protection
11. LED Charge Status Indicator
a. Pre-Charge: Solid Red
b. Bulk Charge: Solid Red
c. Charge Complete: Solid Green
d. No battery or Fault: Green and Red LED off


B) PROTECTION*
01. Over Voltage Protection: 1 cell: 4.6Vdc - 5.0Vdc, 2 cell: 9.2Vdc - 10.0Vdc; 3 cell: 9.2Vdc - 10.0Vdc Charger will terminate charging when over voltage occurs
02. Short Circuit Protection: Charger will not commence charging when BAT+ and BAT- are shorted
03. Reverse Battery Protection: Battery should be mechanically protected from being installed reversed
04. Defective Battery Protection: If battery voltage will not rise above the pre-charge to bulk charge transition voltage (2.86Vdc to 3.15Vdc) within 30 minutes from the time pre-charging begins, the battery is considered defective and the charger will terminate charging.

*When fault condition occurs, the battery has to be removed from the charger and reinstalled after at least 3 seconds to reset the protection. Charging will commence after battery reinstallation only when the fault is cleared.

C) SAFETY
1. Dielectric Withstand Voltage: 4242 Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)


D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 35°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 70°C
05. Cooling: Convection

E) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 60*65*26 +/-1.0 mm
03. Markings: Label and/or Pad Printed and/or Molded in the case
Derating CurveN/A
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)142*60*62
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)45.0
Label Height (mm)50.0
Input Configuration
DescriptionNEMA 1-15P, North America Blades, Class II 2 ConductorsAll NEMA 1 devices are two-wire non-grounding devices (hot-neutral) rated for 125 V maximum. NEMA 1-15P plugs have two parallel flat blades, 0.25 inches (6.35 mm) wide, 0.06 inches (1.524 mm) thick, 0.625-0.718 inches (15.875–18.256 mm) long, and spaced 0.5 inches (12.7 mm) apart.
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added imageIEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: Gen. Req. for Basic Safety &Essential Perf.- Collateral Standard - Req. for Medical Elec. Equip. & Medical Elec.Systems Used in the Home Healthcare Environment
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
2286054.21.0Micro USB type B without resistor
News Releases
TitleWeb Link

Was ist ein AC/DC-Steckernetzteil?

AC/DC-Steckernetzteile oder AC/DC-Adapter sind eine Art externes Netzteil. Einige Elektrogeräte benötigen Strom, es fehlen jedoch die internen Komponenten, um die erforderliche Spannung und Leistung aus dem Stromnetz beziehen zu können. Hier wird ein Netzteil verwendet, das den Wechselstrom in Gleichspannung umwandelt.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?