World map Deutsch

GT-91120-30VV-T3A Wall Plug-in+Desktop Combination ICT/ITE Power Supply Datasheet

Request Information Download PDF Configure Output Connector
GT-91120-30VV-T3A Image
Model Image GT-91120-30VV-T3A, ICT/ITE Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground  ( aka \
Information
Model NumberGT-91120-30VV-T3A
DescriptionGT-91120-30VV-T3A, ICT/ITE Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: ETL; CB 60335;
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O30000008V8P2EAK
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O30000008V8P2EAK
UKCA-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O30000008V8P2EAK
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O30000008V8P2EAK
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination / Stecker-/Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT/ITE Power Supply / ICT/ITE Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress Protection
Size (mm)102*46*37
EnclosureUser-added image
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GT-91120-3007.5-2.5-T3A* 5420
GT-91120-3007.5-1.5-T3A* 63.7522.5
GT-91120-3010.5-1.5-T3A* 92.7724.93
GT-91120-3014.5-2.5-T3A* 122.530
GT-91120-3019.5-4.5-T3A* 15230
GT-91120-3019.5-1.5-T3A* 181.6629.88
GT-91120-3024-T3A* 241.2530
GT-91120-3036-T3A* 360.8329.88
GT-91120-3048-T3A* 480.62530
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: 100-240 Vac
02. Input Current: 0.6 A RMS max
03. Input Frequency: 47 - 63 Hz
04. Output Regulation: +/- 5% measured at the output connector
05. Line Voltage Regulation: +/- 1% typical measured at full load
06. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line
07. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
08. Turn-ON Delay: 3000 mS, maximum @ full load, nominal line
09. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
10. Inrush Current: 30A maximum cold start @ 240Vac input
11. Switching Frequency: 65 KHz typical

B) PROTECTION
01. Over-Voltage: Electronically Protected Zener clamp across the output
02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault
03. Input Protection: Input line fusing

C) SAFETY
01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary
02. Earth Leakage Current: <0.25 mA at 240Vac input voltage
03. ROHS: Complies with EU 2002/95/EC and China SO/T 11363-2006

D) OTHER:
01. MTBF: 200,000 Hours @ 25°C ambient temperature
02. Operating Temperature: 0°C to 40°C ambient temperature
03. Humidity: 0% to 90% relative humidity
04. Storage Temperature: -10°C to 80°C
05. Cooling: Convection

E) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 43.5 x 74.0 x 35.3 mm +/-1.0 mm
03. Markings: Label and/or Pad Printed and/or Molded in the case
Derating Curve
Qty (ea.)/Carton
Individual Box/Gift Box Size (mm)
Individual Box/Gift Box Color
Master Carton Size (mm)TBD
Gross Weight (kg)
Label Width (mm)
Label Height (mm)
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C5 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material. 

Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)
3021066F712(R)N. American (Type B)NEMA 5-15PIEC 320/C518806
1191068F0712(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C524598
2194262M0712(R)Argentina (Type I)IRAM 2073IEC320/C520506.7
2064262M0712(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C520006.6
204B4262M0712(R)Brazil (Type N)BRAZILIEC 320/C520006.6
6023592M5712(R)China (Type I)CCC GR2099IEC 320/C525008
23144262M0712(R)Europe (Type E)CEE 7/7IEC 320/C520506.6
2313K3432M0712(R)Korea (Type F)KS C 8305IEC 320/C520006.6
205IN4262M0712(R)India (Type D)India IS 1293 (also known
as IA16A3 or BS546)
IEC320/C520006.6
377C4262M0712(R)Israel (Type H)ISLIEC320/C520506.7
23024262M0712(R)Italy (Type L)CEI 23-16/VIIIEC 320/C520006.6
3003316F0712(R)Japan (Type B)JIS 8303 / 3 PINSIEC 320/C518306
3021066F0712ULPSE(R)Japan / USA (Type B)JIS 8303 / 3 PINS +
NEMA 5-15P
IEC 320/C518306
2054262M0712(R)S. Africa (Type D)South Africa SABS164-1   (6A type plug)IEC320/C520506.7
2084262M0712(R)S.Africa (Type M)South Africa SABS164-1 (16A type plug)IEC 320/C520006.6
23214262M0712(R)Switzerland (Type J)SEV 1011 ( EL 203)IEC 320/C520006.6
3003316F0712(R)Taiwan (Type B)BSMIIEC 320/C520006.6
6104262M0712(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C520006.6
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added imageAAMI ES60601-1:2005 +A1 - Medical Electrical Equipment - Part 1: General Requirements CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1 IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.
User-added imageUKCA Certification
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
17984012.02500.0Female Barrel 5.5 * 2.5 * 9mm No internal Spring Clip nor Locking Notch or Equal
News Releases
TitleWeb Link

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Was ist ein Steckernetzteil/Tischnetzteil?

Stecker-/Tischnetzteile werden auch als AC-Adapter oder AC/DC-Wandler bezeichnet und sind eine Art externes Netzteil. Diese Geräte können mit einem standardmäßigen IEC 60320-Netzkabel oder mit dem eigenen Eingangssteckersystem als Steckernetzteile verwendet werden und ohne Kabel direkt in die Steckdose gesteckt werden. Einige Elektrogeräte benötigen Strom, es fehlen jedoch die internen Komponenten, um die erforderliche Spannung und Leistung aus dem Stromnetz beziehen zu können. Hier wird ein Netzteil verwendet, das den Wechselstrom in Gleichspannung umwandelt.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?