GT-TDIN1-5000VVV DIN Rail ICT/ITE Power Supply Datasheet
GT-TDIN1-5000VVV Image | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Image | ![]() | ||||||||||||
Information | |||||||||||||
Model Number | GT-TDIN1-5000VVV | ||||||||||||
Description | GT-TDIN1-5000VVV, ICT/ITE Power Supply, DIN Rail, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), Terminal Block, Output Rating: 24 Watts, Power rating with convection cooling (W) , 24V in 0.1V increments, Approvals: GT-TDIN1-5000VVV, ICT/ITE Power Supply, DIN Rail, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz), Terminal Block, Output Rating: 24 Watts, Power rating with convection cooling (W) , 24V in 0.1V increments, Approvals: | ||||||||||||
Agency Documents | http://en.globtek.com/safety-agency-documents-pending/ | ||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||
Morocco SDoC Declaration | https://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000FiYnbEAF | ||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000FiYnbEAF | ||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||
Model Parameters | |||||||||||||
Type | DIN Rail / Hutschiene | ||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||
Category | ICT/ITE Power Supply / ICT/ITE Power Supply | ||||||||||||
Input Voltage Range (V) | 90 ~ 264VAC, 127 ~ 370VDC (47 ~ 63Hz) | ||||||||||||
Max Input Current (A) | 0.4A | ||||||||||||
Max Output Power Rating (W) | 24 | ||||||||||||
Output Voltage Range (V) | 24 | ||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||
Ingress Protection | IP20 | ||||||||||||
Size (mm) | 210(L)*110(W)*109.5(H) | ||||||||||||
Enclosure | | ||||||||||||
Rating Table | |||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||
Specifications | |||||||||||||
01. Input Voltage: 90-264VAc, 127-380VDc 02. Input current: 0.4A RMS Max. 03. Input Frequency: Specified 47-63 Hz 04. Each output can provide up to maximum load, but total load can not exceed rated output power. 05. Line regulation is measured from low line to high line at rated load. 06. Load regulation is measured from 20% to 100% of rated load at 220VAC input. (Redundant function Sepc. 0.6V Add.) 07. Ripple & Noise are measured with 20MHz oscilloscope at 220VAC by using a 20cm long 12” twisted pair-wire with a 0.1uF/630V metal capacitor & a 47uF electrolytic capacitor parallel on the test point. 08. Efficiency is measured at rated load and 220VAC input. 09. Hold-up time is measured at rated load and 220VAC input. 10. Output Voltage Adjustable is measured on 5% of rated load. 11. Hold-Up Time: 10 mS at rated power 12. Power Factor: 95% Min. B) PROTECTION 01. Over load protection Constant current protection 02. Over voltage protection Autorecovery 03. Short protection Autorecovery D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature, 77,500 Hours at 45°C 02. Operating Temperature: -15°C to +50°C ambient temperature 03. Humidity: 0% to 90% relative humidity Non Condensing 04. Storage Temperature: -20°C to 85°C 05. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11363-2006 E) ENCLOSURE 01. Size: 210*110*109.5 +/-1.0 mm 02. Weight: 1790 g maximum 03. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||
Derating Curve | N/A | ||||||||||||
Qty (ea.)/Carton | 60 | ||||||||||||
Individual Box/Gift Box Size (mm) | 100*53*65 | ||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||
Master Carton Size (mm) | 415 x 280 x 230 | ||||||||||||
Gross Weight (kg) | 7.4 | ||||||||||||
Label Width (mm) | 24.7 | ||||||||||||
Label Height (mm) | 27.7 | ||||||||||||
Input Configuration | |||||||||||||
Description | Terminal Block | ||||||||||||
Popular Products (Stock items) | |||||||||||||
|
Was ist eine Effizienz nach Level VI?
Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.
Ist eine Effizienz nach Level VI erforderlich?
Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.
Was ist die Ökodesign-Richtlinie 2009/125/EG?
Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.
Wie funktioniert ein AC/DC-Adapter?
Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.