GTM961200P120VV.V-T3A Desktop/External ICT / ITE / Medical Power Supply Datasheet

GTM961200P120VV.V-T3A
GTM961200P120VV.V-T3A, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground  ( aka \GTM961200P120VV.V-T3A, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 61347; RCM; CCC; Morocco; EAC; cETLus; cETLus 60601-1-11; Malaysia; Taiwan BSMI (12,15,18,19,24,48,54V only); South Africa; ETL; S-Mark 60950; CB 61347; ETL; CB 60335; VCCI; CB 60601-1; S-Mark; WEEE; Ukraine; RoHS; ETL 62368; Level VI; China RoHS; CE;Class I; PSE; PSE; PSE; ETL (Brazil); S-Mark 62368; IRAM; Korea (12V and 13V Only); UKCA; Conforms to 62368-1; NrCAN (12V only); CB 60335; CB 62368;
Information
Model NumberGTM961200P120VV.V-T3A
Agency Documentshttp://www.globtek.info/certs/GTM961200P/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000NKYPKEA5
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000NKYPKEA5
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000NKYPKEA5
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000NKYPKEA5
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000NKYPKEA5
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000NKYPKEA5
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Externes Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply / ICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5 A
Max Output Power Rating (W)120
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP41
Size (mm)149.30*62.80*34.00
EnclosureUser-added image
 
3D File Downloadhttps://globtek.my.salesforce.com/servlet/servlet.ExternalRedirect?url=https%3A%2F%2Fwww.globtek.com%2Fdl%2FGTM96900-GTM961200-T3A.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM961200P11012-T3A*129.2110.4
GTM961200P11013-T3A*138.54111.02
GTM961200P11014-T3A*147.93111.02
GTM961200P12015-T3A*158120
GTM961200P12016-T3A*167.5120
GTM961200P12017-T3A*177.06120.02
GTM961200P12018-T3A*186.66119.88
GTM961200P12019-T3A*196.316120
GTM961200P12020-T3A*206120
GTM961200P12021-T3A*215.71119.91
GTM961200P12022-T3A*225.45119.9
GTM961200P12023-T3A*235.21119.83
GTM961200P12024-T3A*245120
GTM961200P12025-T3A*254.8120
GTM961200P12026-T3A*264.61119.86
GTM961200P12027-T3A*274.44119.88
GTM961200P12028-T3A*284.28119.84
GTM961200P12029-T3A*294.13119.77
GTM961200P12030-T3A*304120
GTM961200P12031-T3A*313.87119.97
GTM961200P12032-T3A*323.75120
GTM961200P12033-T3A*333.63119.79
GTM961200P12034-T3A*343.53120.02
GTM961200P12035-T3A*353.42119.7
GTM961200P12036-T3A*363.33119.88
GTM961200P12037-T3A*373.24119.88
GTM961200P12038-T3A*383.15119.7
GTM961200P12039-T3A*393.07119.73
GTM961200P12040-T3A*403120
GTM961200P12041-T3A*412.92119.72
GTM961200P12042-T3A*422.85119.7
GTM961200P12043-T3A*432.79119.97
GTM961200P12044-T3A*442.72119.68
GTM961200P12045-T3A*452.66119.7
GTM961200P12046-T3A*462.6119.6
GTM961200P12047-T3A*472.55119.85
GTM961200P12048-T3A*482.5120
GTM961200P12049-T3A*492.44119.56
GTM961200P12050-T3A*502.4120
GTM961200P12051-T3A*512.35119.85
GTM961200P12052-T3A*522.3119.6
GTM961200P12053-T3A*532.26119.78
GTM961200P12054-T3A*542.22119.88
GTM961200P120VV.V-T3A-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
     100% rated load current for 90-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:< 150mW @ 115/230VAC
Inrush Current:< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ.
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:5% max.
Transient Response:5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Power Indicator:Green LED
Switching Frequency:Variable, 25KHz - 125KHz, depending on load

Protections

Input Protection:300VAC MOV transient suppressor, input line fusing
Over-Current ProtectionCurrent limited to less than < 170W / Vout(nom.) and  < 13A, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature ProtectionInternal ambient NTC temperature sensor, latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option
 

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 70µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:C6, C8, C14, or C18 IEC inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Reduced leakage current to meet IEC60601-1 Type-CF limits
  2. Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
  3. Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C) for 85 - 120W load
  4. Short term output surge capability for motors or other high peak current loads
  5. Ruggedized construction with improved shock and vibration resistance
  6. Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  7. Custom cordsets, special cordage and connector types
  8. Custom housing markings
  9. Custom housing/cordage colors
  10. Tightened output voltage tolerance
  11. Reduced output ripple level
  12. Reduced output power rating
  13. Low temperature option, down to -40°C
  14. Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
  15.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  16. Improved ingress protection (IP) rating

Output Connectors

 

Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)11.3
Label Width (mm)50
Label Height (mm)110
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C5 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material. 

Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)
3021066F712(R)N. American (Type B)NEMA 5-15PIEC 320/C518806
1191068F0712(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C524598
2194262M0712(R)Argentina (Type I)IRAM 2073IEC320/C520506.7
2064262M0712(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C520006.6
204B4262M0712(R)Brazil (Type N)BRAZILIEC 320/C520006.6
6023592M5712(R)China (Type I)CCC GR2099IEC 320/C525008
23144262M0712(R)Europe (Type E)CEE 7/7IEC 320/C520506.6
2313K3432M0712(R)Korea (Type F)KS C 8305IEC 320/C520006.6
205IN4262M0712(R)India (Type D)India IS 1293 (also known
as IA16A3 or BS546)
IEC320/C520006.6
377C4262M0712(R)Israel (Type H)ISLIEC320/C520506.7
23024262M0712(R)Italy (Type L)CEI 23-16/VIIIEC 320/C520006.6
3003316F0712(R)Japan (Type B)JIS 8303 / 3 PINSIEC 320/C518306
3021066F0712ULPSE(R)Japan / USA (Type B)JIS 8303 / 3 PINS +
NEMA 5-15P
IEC 320/C518306
2054262M0712(R)S. Africa (Type D)South Africa SABS164-1   (6A type plug)IEC320/C520506.7
2084262M0712(R)S.Africa (Type M)South Africa SABS164-1 (16A type plug)IEC 320/C520006.6
23214262M0712(R)Switzerland (Type J)SEV 1011 ( EL 203)IEC 320/C520006.6
3003316F0712(R)Taiwan (Type B)BSMIIEC 320/C520006.6
6104262M0712(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C520006.6
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016
User-added imageRCM certificate GMA-514113-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
User-added image
Serial Number Information
No Logo Malaysia ST Release Letter GTM961200P T2 T3(A) IEC62368-1(Ed.2): No logo
User-added imageTaiwan BSMI GTM961200P-T3(A) R32282 GTM961200P-T3(A); http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2
 No LogoSOUTH AFRICAN EMI/EMC SABS
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]

No Logo Applicable

IEC 60335-1.2010+A1
User-added imageJapan: Voluntary Control Council for Interference (VCCI)

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/


 
ETL (Brazil) to IEC 62368-1;2014 DOC cert
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificate DC-E-G71-005.1 to IEC 62368-1:2014
User-added imageKorea KET KC Mark GTM961200P11012-T3(A) HU10499-21046A (12V & 13V Only)
User-added image
 
UKCA Certification
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageNatural Resources Canada (NRCan): CSA Standard C381.1-08, QSP NRCAN EEV1191; for model: GTM961200P10812-T3, -T3A, -T3TAB, -T2, -T2A, http://shop.csa.ca/en/canada/energy-efficiency/cancsa-c3811-08/invt/27024802008

No Logo Applicable

IEC 60335-1.2010+A1

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
252297819.06.316
219283330.04.0
240783019.06.316

Was ist ein IEC 60601-1-11-Netzteil für die Medizintechnik im Hausgebrauch?

Die FDA definiert ein Medizinprodukt für den Hausgebrauch als ein Gerät für Benutzer in einer nichtklinischen oder vorübergehenden Umgebung, das teilweise oder vollständig vom Benutzer verwaltet wird. Es erfordert eine angemessene Kennzeichnung für den Benutzer. Außerdem ist gegebenenfalls eine Einweisung des Benutzers durch medizinisches Fachpersonal notwendig, um eine sichere und effektive Nutzung sicherzustellen. Dies umfasst permanent und vorübergehend implantierte Geräte und alle Arten von Geräten, die zur Genesung oder Rehabilitation einer Person eingesetzt werden können. IEC 60601-1-11 ist die aktuelle Version der Basisnorm IEC 60601-1, die sich auf die grundlegende Sicherheit und die wesentlichen Leistungsmerkmale medizinischer elektrischer Geräte in Wohnbereichen bezieht. Mit Wirkung zum 30. Juni 2013 in der Europäischen Union und zum 31. Dezember 2013 in den USA unterscheidet sich der neue Standard in mehreren wesentlichen Punkten von den vorherigen Ausgaben. Der Standard setzt jetzt eine Zuordnung der medizinischen Geräten zu der Klasse II, einen erhöhten Schutz vor Eindringen (IP-Schutzart) und Systeme für den Heimgebrauch voraus. Der Begriff des Wohnbereiches bezieht nun auch europäische Pflegeheime mit ein. Ein IEC 60601-1-11-Netzteil für die Medizintechnik im Hausgebrauch ist ein AC/DC-Wandler, der den in IEC 60601-1-11 festgelegten Standards entspricht. Abgesehen von den grundlegenden Anforderungen an medizinische Netzteile, wie eine erhöhte dielektrische Spannungsfestigkeit und ein geringer Ableitstrom, müssen die Netzteile für die häusliche Pflege auch der Klasse II zugeordnet sein und mindestens der Schutzart IP21 entsprechen. IEC 60601-1-11 ist auch in CB, UL und anderen Produktprüfberichten aufgeführt.


Woher weiß ich, ob ich einen Netzteiladapter für die Medizintechnik im Hausgebrauch nach IEC 60601-1-11 benötige?

Die Endanwendung und der Ort, an dem das Gerät eingesetzt wird, entscheiden, ob IEC 60601-1-11 eingehalten werden muss.


Gibt es Einschränkungen hinsichtlich der Art des Netzteils, die IEC 60601-1-11 einhalten könnte?

Die meisten GlobTek-Netzteile für den medizinischen Hausgebrauch und AC/DC-Adapter von GlobTek sind nach IEC 60601-1-11 zertifiziert. GlobTek bietet sowohl externe Tischnetzteile als auch Steckernetzteile an, die dem Standard entsprechen. Ein AC/DC-Adapter nach IEC 60601-1-11 unterscheidet sich von anderen Modellen hauptsächlich insofern, dass er der Klasse II zugeordnet ist und eine höhere IP-Schutzart aufweist.

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Ist für die Stromversorgung über Ethernet (Power over Ethernet) eine Effizienz nach Level VI erforderlich?

Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt.Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt. Im Allgemeinen erfüllen alle Netzteile für die Stromversorgung über Ethernet (PoE) alle Kriterien und müssen eine Effizienz nach Level VI aufweisen.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist eine Effizienz nach Level VI?

Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.


Ist eine Effizienz nach Level VI erforderlich?

Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.


Was ist die Ökodesign-Richtlinie 2009/125/EG?

Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.

Was ist IEC 60335-1?
Die internationale Norm 60335-1 regelt die Sicherheit von Elektrogeräten für den Haushalt und ähnliche Zwecke mit einer Nennspannung von nicht mehr als 250 V für einphasige Geräte und 480 V für andere Geräte.

Warum muss ein Netzteil oder ein AC-Adapter nach IEC 60335-1 zertifiziert sein?
Anwendungen, die im Haushalt verwendet werden, müssen ein nach IEC 60335-1 zertifiziertes Netzteil oder einen nach IEC 60335-1 zertifizierten AC/DC-Wandler verwenden. Diese einzigartigen Netzteile erfüllen die Anforderungen, die für Haushaltsgeräte gelten. What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI).

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?