DOE Level VI Steckernetzteil / Ladegerät / AC Adapter, 6W, erhältlich mit 5-24VDC Ausgangsspannung

GTM96060-06VV-Q Image
Model ImageGTM96060-06VV-Q, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-36V in 0.1V increments, Approvals: CCC; PSE; CAN ICES-3; IP42; CB 62368; 230V CoC Tier 2; ETL; EAC; cETLus 60950-1; cETLus 60601-1-11; UL 1310; UKCA; India BIS 5V, 5.5V,5.95V, 7.5V, 9V, 12V, 15V,18V, 19V, 24V; UL 1310; Korea (9,9.5,10,11,12,13,13.5,14V Only); Taiwan BSMI; Conforms to 62368-1; ETL 62368; LPS 62368; Morocco; ETL (Brazil); PSE; CB 60601-1 2MOPP; CB EN/IEC 60335-1; S-Mark IEC/EN 60601-1; S-Mark 60950; cETLus UL1310; CE; Double Insulation; CE; China RoHS; Level VI; LPS 60950; RoHS; Ukraine; VCCI; WEEE; CB 60950; cETLus 60601-13rd; RCM; Korea (5.0V,5.2V,5.5V,5.6V,5.95V,6V,6.7V and 7.5V Only); PSE; PSE; FCC; GTM96060-06VV-Q, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-36V in 0.1V increments, Approvals: CCC; PSE; CAN ICES-3; IP42; CB 62368; 230V CoC Tier 2; ETL; EAC; cETLus 60950-1; cETLus 60601-1-11; UL 1310; UKCA; India BIS 5V, 5.5V,5.95V, 7.5V, 9V, 12V, 15V,18V, 19V, 24V; UL 1310; Korea (9,9.5,10,11,12,13,13.5,14V Only); Taiwan BSMI; Conforms to 62368-1; ETL 62368; LPS 62368; Morocco; ETL (Brazil); PSE; CB 60601-1 2MOPP; CB EN/IEC 60335-1; S-Mark IEC/EN 60601-1; S-Mark 60950; cETLus UL1310; CE; Double Insulation; CE; China RoHS; Level VI; LPS 60950; RoHS; Ukraine; VCCI; WEEE; CB 60950; cETLus 60601-13rd; RCM; Korea (5.0V,5.2V,5.5V,5.6V,5.95V,6V,6.7V and 7.5V Only); PSE; PSE; FCC;
Information
Model NumberGTM96060-06VV-Q
DescriptionGTM96060-06VV-Q, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-36V in 0.1V increments, Approvals: CCC; PSE; CAN ICES-3; IP42; CB 62368; 230V CoC Tier 2; ETL; EAC; cETLus 60950-1; cETLus 60601-1-11; UL 1310; UKCA; India BIS 5V, 5.5V,5.95V, 7.5V, 9V, 12V, 15V,18V, 19V, 24V; UL 1310; Korea (9,9.5,10,11,12,13,13.5,14V Only); Taiwan BSMI; Conforms to 62368-1; ETL 62368; LPS 62368; Morocco; ETL (Brazil); PSE; CB 60601-1 2MOPP; CB EN/IEC 60335-1; S-Mark IEC/EN 60601-1; S-Mark 60950; cETLus UL1310; CE; Double Insulation; CE; China RoHS; Level VI; LPS 60950; RoHS; Ukraine; VCCI; WEEE; CB 60950; cETLus 60601-13rd; RCM; Korea (5.0V,5.2V,5.5V,5.6V,5.95V,6V,6.7V and 7.5V Only); PSE; PSE; FCC; GTM96060-06VV-Q, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-36V in 0.1V increments, Approvals: CCC; PSE; CAN ICES-3; IP42; CB 62368; 230V CoC Tier 2; ETL; EAC; cETLus 60950-1; cETLus 60601-1-11; UL 1310; UKCA; India BIS 5V, 5.5V,5.95V, 7.5V, 9V, 12V, 15V,18V, 19V, 24V; UL 1310; Korea (9,9.5,10,11,12,13,13.5,14V Only); Taiwan BSMI; Conforms to 62368-1; ETL 62368; LPS 62368; Morocco; ETL (Brazil); PSE; CB 60601-1 2MOPP; CB EN/IEC 60335-1; S-Mark IEC/EN 60601-1; S-Mark 60950; cETLus UL1310; CE; Double Insulation; CE; China RoHS; Level VI; LPS 60950; RoHS; Ukraine; VCCI; WEEE; CB 60950; cETLus 60601-13rd; RCM; Korea (5.0V,5.2V,5.5V,5.6V,5.95V,6V,6.7V and 7.5V Only); PSE; PSE; FCC;
Agency Documentshttp://www.globtek.info/certs/GTM96060/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000NrvDbEAJ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000NrvDbEAJ
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000NrvDbEAJ
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000NrvDbEAJ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000NrvDbEAJ
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000NrvDbEAJ
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000NrvDbEAJ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000NrvDbEAJ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in / Steckergerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A
Max Output Power Rating (W)6
Output Voltage Range (V)3.3-36
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP42 (Optional IP54-IP55)
Size (mm)43.5*74.0*36.8
Enclosure


User-added image
LED INDICATOR: Green Power ON indicator LED standard. May be ordered without LED as an option
 

3D File Downloadhttps://www.globtek.com/dl/GTM96180-WALL-PLUG%20(5).igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM96060-0706-1.0*51.57.5
GTM96060-0606-1.0*51.26
GTM96060-0606-0.05*5.9515.95
GTM96060-0612-3.0*90.665.94
GTM96060-0512-3.0*90.54.5
GTM96060-0612-2.5*9.50.635.99
GTM96060-0612*120.56
GTM96060-0615-1.5*13.50.445.94
GTM96060-0615*150.46
GTM96060-0618*180.3335.99
GTM96060-0624-5.0*190.3166
GTM96060-0624-4.0*200.36
GTM96060-0624*240.256
GTM96060-0636-6.0*300.26
GTM96060-0636*360.1665.98
GTM96060-06VV-Q-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC
Inrush Current:<30A @ 230VAC (cold start @ 25°C)
Efficiency:DoE Energy Level VI and CoC Tier 2, for models 5V and above

Output

Turn-on Delay:1 second max. @ 100VAC and full load
Output Regulation± 5% (measured at the output connector)
Line Regulation:± 1%  (measured at the output connector @ full load)
Ripple:0.5% pk-pk or 50mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
(Note: < 0.2% or 25mV option available upon request)
Transient Response:5% deviation max. (with 25% load step), recovery to within 1ms typ.
Startup Overshoot:<5% (full load)
Hold-up Time:8ms min. (100VAC and full load)
Power Indicator:Green LED
Switching Frequency:65KHz typ.

Protections

Input Protection:300Vac MOV transient suppressor, input line fusing
Over-Voltage Protection:110-130%, of nominal output voltage
Current Limiting:
(Standard CV Models):
Short circuit and overload protected, auto recovery
Output current limit: 120% to 250% of rated output current
(Upper end of current limit range is determined by normal output power rating, not derated output power level)
Current Limiting:
(Constant Current Models):
± 10% of specified nominal output current rating
Current regulated from Vout (nom.) to 0.25 * Vout (nom.)
Average output current below 0.25 * Vout will be reduced, and unit will hiccup cycle
Over-Temperature ProtectionOn-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~140°C, restart at Tj = ~70°C

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 50°C (@ 6W load)
See derating graph for output power capability outside of standard range.
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Cooling:Convection
RoHS:Compliant with latest regulations

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
Touch Current:<60µA
Earth Leakage CurrentN/A, Class II input (No protective earth pin, therefore earth leakage is not measured)
Means of Protection:2 x MOPP
Primary-Secondary Bridging Capacitance:Two 470pF IEC60384-14 certified Y1 capacitors in series

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 1.5KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:43.5 x 74.0 x 36.8 +/-1.0 mm
Markings:Label, pad printing, or laser engraving

Special Options

  1. Cost reduction, removal of LED
  2. Custom cordsets, various cordage types, and connector types
  3. Custom markings
  4. Reduced leakage current version, medical Type-CF leakage current compliance
  5. Tightened output voltage tolerance
  6. Reduced output ripple level
  7. Constant current battery charger characteristic
  8. Reduced output power rating
  9. High reliability PCB laminate with plated through-holes for IPC610 Class 2 Compliance
  10. Output voltage between 3.3V and 4.9V (without DoE EL6 and EU CoC Tier 2  compliance)
  11. Special housing colors and cordset colors
  12. Tamper proof, AC wall plug-in blade assembly. (Requires a special tool to remove the AC Wall Plug-in blade assembly.)
Derating CurveUser-added image
 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)480 x 450 x 205
Gross Weight (kg)15.2
Label Width (mm)29.8
Label Height (mm)20.8
Input Configuration
DescriptionBlade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php
Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf
Video: Q-Blade Style Instruction Video


User-added image
 

INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified

01. United States / Canada / Japan  NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R)
02. Australian AS 3112 configuration: SAA 2 blade/ IEC TYPE I, Class II; AU P/N: Q-SAA(R)
03. UK BS 1363 configuration: UK 3 blade with dummy Ground/ IEC TYPE G, Class II; GB P/N: Q-UK(R)
04. European CEE 7/16 configuration: Europlug 2 pins/ IEC TYPE C [WORKS IN TYPE E&F], Class II; EU P/N: Q-EU(R)
05. Korean KS C8305 configuration: 2 pins/SIMILAR TO IEC TYPE C, Class II; KR P/N: Q-KR(R)
06. Argentina IRAM 2073 configuration: 2 blades/SIMILAR TO IEC TYPE I; AR P/N: Class II Q-AR(R)
07. China GB 2099 configuration: 2 blades/SIMILAR TO TYPE A, Class II; CN P/N:Q-CN(R)
08. India IS 1293 6A/BS546 configuration: 5A, 3 pins with Dummy Ground, Class II/IEC TYPE D; IN P/N: Q-IN(R)
09. IEC60320/C18 Inlet, Class II; P/N: Q-C18(R)
10. Brazilian NBR6147 configuration: 2 pins, Class II;SIMILAR TO IEC TYPE C BR P/N: Q-BR(R)
11. South Africa SABS164-1 and India
 IS 1293, IS694, 16A type plug, 3 round prongs, Class II + dummy ground, IEC TYPE M P/N: Q-SANS164-1-16A(R)
12. South Africa SABS164-4, 3 round prongs with a notched prong @ 0º, Class II + dummy ground, IEC TYPE M Red, P/N:
Q-SANS164-4L-16A(R)
13. South Africa SABS164-4, 3 round prongs with a notched prong @ -
53º, Class II + dummy ground, Blue, IEC TYPE M, P/N:
Q-SANS164-4C-16A(R)
14. South Africa SABS164-4, 3 round prongs with a notched prong @ +53º, Class II + dummy ground, Black,IEC TYPE M P/N:
Q-SANS164-4R-16A(R)

Kits

01. Q-KIT: 1,2,3,4 above
02. Q-KIT-INTL: 2,3,4 above
03. Q-KIT-6: 1,2,3,4,5,6 above
04. Q-KIT-7: 1,2,3,4,5,6,7 above
05. Q-KIT-8: 1,2,3,4,5,6,7,8 above

Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2 for 5V and > models, 278/2009, Mar 2014
 User-added image
 
Taiwan BSMI; http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2 GTM96060-0606-1.0
No Logo ApplicableCB report IEC60601-1 2005 A1+C1+C2 2016-2-4 and or EN 60601-1:2006 3.1rd Edition 2xMOPP
No Logo CB Report IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 (GTM96060-WWXX)

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)

No Logo Applicable

CB to 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image
 
CCC to GB4943.1-2011 GB9254-2008 GB17625.1-2012
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN61000-3-2, EN61000-3-3 and EN50082-1, including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61001-1-2-2007 EMI: Complies with EN55011 CLASS B and FCC Part 15 B
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27, Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued: 2007/03/27 Ed: 2 (R2012) Amd.
User-added image
Class 2 Power Unit
 
cETLus-Cert 4007497 UL1310 Recognized Component up to 36 volts
User-added image
 
AAMI ES60601-1 Issued: 2012/08/20 Medical Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11:
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Certification # TC RU AR46.B.69004 Custom Union of Russia, Belarus and Kazakhstan


 
ETL (Brazil) to IEC 62368-1;2014 DOC cert
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added image
 
INDIA BIS (GTM96060) 5V,5.5V, 5.95V, 7.5V, 9V, 12V,15V, 18V, 19V, 24V only
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
JAPAN TUV R-PSE, Cert. No. JD 50471624, to J62368-1(H30) , J55032(H29),J3000(H25,[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471624, to J62368-1(H30) , J55032(H29),J3000(H25,[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471624 J62368-1(H30) , J55032(H29),J3000(H25),[DC15V?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471624, to J62368-1(H30) , J55032(H29),J3000(H25),[DC30V?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added image
 
Korea KC Mark GTM96060-Q HU10499-20043A (5.0V,5.2V,5.5V,5.6V,5.95V,6V,6.7V and 7.5V Only)
User-added image
 
Korea KC Mark GTM96060-Q (9,9.5,10,11,12,13,13.5,14V Only)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe) (for 5V and > models)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageRCM certificate SAA-210640-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageSemko S-Mark-Cert-EN60601-1 3.1rd Edition (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample RequestDistributor Stock (Click to order)
5509313.31.8T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
6729299.00.66Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
38473412.00.53.5*14mm mono plug
WR9QE500CCPNAIMR6B12.00.5Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal107

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist eine Effizienz nach Level VI?

Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.


Ist eine Effizienz nach Level VI erforderlich?

Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.


Was ist die Ökodesign-Richtlinie 2009/125/EG?

Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.

Was ist die EU-Verordnung CoC Tier 2?
Die EU-Verordnung CoC-Tier-2 umfasst eine Reihe von Effizienzzielen für externe Netzteile und AC-Adapter, die von der Abteilung für erneuerbare Energien der GFS (Gemeinsame Forschungsstelle) der Europäischen Kommission veröffentlicht wurden. Es handelt sich um freiwillige Maßnahmen, die gesetzlich nicht vorgeschrieben sind.

Was ist ein AC/DC-Steckernetzteil?

AC/DC-Steckernetzteile oder AC/DC-Adapter sind eine Art externes Netzteil. Einige Elektrogeräte benötigen Strom, es fehlen jedoch die internen Komponenten, um die erforderliche Spannung und Leistung aus dem Stromnetz beziehen zu können. Hier wird ein Netzteil verwendet, das den Wechselstrom in Gleichspannung umwandelt.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern

Model

GT-83084-WWVV-USB-W2AR

Argentina Wall Plug in, 2 Prong, 5V 2A Adapter with USB A

GTM46101-WWVV-X.X-USB

60601-1 Medical DOE EPS 2.0 Level VI Power Supply / Charger, 5v, 2.0A, with integral USB Jack, compliant with 2MOPP, 5000 Meters Elevation and 8 kV Contact/20kV Air Discharge ESD Protection

Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?