Model Image GTM96600-60VV.V-R2, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: Korea (41V-54V Only); CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; South Africa; EAC; cETLus 60601-1-11; cETLus 60950-1; UL 1310; CB 62368; Taiwan BSMI; India; UKCA; UL 1310; CB 61158; NRCan (5V only); Morocco; ETL 60950; S-Mark 60950; RCM; CB 60950; Double Insulation; CB 60601-1; S-Mark IEC/EN 60601-1; CCC; cETLus 60601-1; LPS 60950; PSE; PSE; PSE; CE; China RoHS; Level VI; RoHS; Ukraine; VCCI; WEEE;
Information
Model NumberGTM96600-60VV.V-R2
DescriptionGTM96600-60VV.V-R2, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: Korea (41V-54V Only); CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; South Africa; EAC; cETLus 60601-1-11; cETLus 60950-1; UL 1310; CB 62368; Taiwan BSMI; India; UKCA; UL 1310; CB 61158; NRCan (5V only); Morocco; ETL 60950; S-Mark 60950; RCM; CB 60950; Double Insulation; CB 60601-1; S-Mark IEC/EN 60601-1; CCC; cETLus 60601-1; LPS 60950; PSE; PSE; PSE; CE; China RoHS; Level VI; RoHS; Ukraine; VCCI; WEEE;
Agency Documentshttp://www.globtek.info/certs/GTM96600-TZ/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MmH0aEAF
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MmH0aEAF
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MmH0aEAF
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MmH0aEAF
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MmH0aEAF
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MmH0aEAF
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination / Stecker-/Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5 A
Max Output Power Rating (W)60
Output Voltage Range (V)5-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP40, IP54 Option available
Size (mm)117.53*53.47*36.6
EnclosureUser-added image

User-added image

Unit shipped without an installed input plug.            
 “Desktop insert” installed.

 
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM96600-2505-R2* 5525
GTM96600-4005-R2* 5840
GTM96600-4005.95-R2* 5.956.7239.98
GTM96600-4507.5-R2* 7.5645
GTM96600-5409-R2* 9654
GTM96600-6012-R2* 12560
GTM96600-6015-1.2-R2* 13.84.3459.89
GTM96600-6015-R2* 15460
GTM96600-6018-R2* 183.33359.99
GTM96600-6019-R2* 193.1559.85
GTM96600-6020-R2* 20360
GTM96600-6024-R2* 242.560
GTM96600-6030-R2* 30260
GTM96600-6048-R2* 481.2560
GTM96600-6054-R2* 541.1159.94
GTM96600-60VV.V-R2-XXXXCUSTOM CUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant) for ≤ 49W rating
<150mW @ 230VAC (EU CoC Tier 2 compliant) for > 49W rating
Inrush Current:30A/60A max. (cold start @ 115V/230VAC)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ 115VAC and full load
Output Regulation:± 5% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector)
Ripple:1% or 100mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation, 1ms typ. recovery time (with 40% to 70% load step)
Hold-up Time:8ms typ. (nominal input voltage and full load)
Power Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Current Protection:110 - 160% of rated output current, auto-restart, current limit range determined by normal output power rating, not de-rated power rating
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 130%, latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 85µA max.
Class II F2: 20µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Desktop: C6, C7, C14, or C18 inlet
Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Removal of LED (cost reduction or aesthetic purpose)
  2. Custom cordsets, various cordage types, and connector types
  3. Custom markings
  4. Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
  5. Reduced leakage current
  6. Tightened output voltage tolerance
  7. Reduced output ripple level
  8. Reduced output power rating
  9. High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
  10. Low temperature option, down to -40°C
  11. Special housing and cordset colors
  12.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  13. Improved ingress protection (IP) rating

Output Connectors

 

Derating CurveUser-added image
     
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)44.5
Label Height (mm)49.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C8 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
1. Class II model NEMA 1-15P AC power plug with 2 prongs, R-NA-2(R) 
2. Australian AS 3112 configuration: SAA 2 pins Class II, R-SAA-2(R) 
3. UK BS 1363 configuration: UK 2 pins (dummy Ground) Class II, R-UK-2(R) 
4. European CEE 7/16 configuration: Europlug 2 PINS, Class II, R-EU-2(R) 
5. China GB 2099 configuration: 2 blades, Class II; CN P/N:R-CN-2(R)
6. Desktop Insert
Kits
05. R-KIT-2(R): 1,2,3,4 above
06. R-KIT-2-INTL(R): 2,3,4 above

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
 
Part NumberCountryPlugConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703B(R)India (Type M)BS 546IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageBook 60335 up to 36 Volts
User-added imageTaiwan BSMI GTM96600-R2 T2 R32282 GTM96600-6048-R2; http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2

No Logo Applicable

CB for IEC 60335-1:2010+A1

No Logo Applicable

IEC 60601-1:2005+A1 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60950-1:2005+A1+A2

No Logo Applicable

IEC 61558-1:2005+A1, IEC 61558-2-16:2009+A1

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image
仅适用于海拔5000米以下地区使
 
CCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032:2012+AC:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [AAMI ES60601-1:2005 +A1]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision:01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
User-added imageBureau Of Indian Standards for GTM96600-4005-R2, GTM96600-4005-T2, GTM96600-6012-T2, GTM96600-6012-R2, GTM96600-6015-T2, GTM96600-6015-R2, GTM96600-6024-T2, GTM96600-6024-R2, GTM96600-6048-R2,,GTM96600-6026-P2
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageKorea HU10499-19039A (for GTM96600-6x48-T2,R2(41V-54V)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageCanadian Energy Efficiency Regulations incorporating amendments 1 (only for model GTM96600-4005 only)
User-added imageRCM certificate ; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006+A1+A12, EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
 No LogoSouth Africa approval to SANS IEC 60950
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
RR9KA8000LCPIM(R6B)5.08.0Female Barrel 5.5 * 2.5 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 5
RR9KA8000CCPIM(R6B)5.08.0Female Barrel 5.5 * 2.1 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A 37
3249315.08.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
2875915.05.0RP34L-5PA-3SC(71)
2289805.06.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
17286815.05.0USB Type-C Connector
5294365.05.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
5061165.05.0RP34L-5PA-3SC(71)
RR9KB6667T00CIMR6B5.956.72T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 40
RR9KC6000T00CIMR6B7.56.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 58
RR9KD6000T00CIMR6B9.06.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 50
133476412.05.0Stripped 25.0 +/- 1mm; Stripped 15.0 +/- 1mm, Tinned 5 +/- 1mm
165718712.05.0Stripped 25+/-5mm, Tinned 8+/-2mm with Black Thermal Contracting Sleeve length 10 +3/-1mm or Equal
72166312.05.0DC Power connector, locking, 5.5*2.1mm, 12mm insertion depth; Equiv to S761K & 767K; mates with L722A, PCL722A
23029612.05.0Waterproof IP68 Molded Male Plug, 2 Pins, Equivalent to KCC SK2/2 MALE
24946912.05.0Female Barrel 5.5 * 2.5 * 9.5mm with internal Spring Clip and Locking Notch or Equal
134336512.05.0Female Barrel 5.5 * 2.1 * 13.8 mm w/ 6.5mm Thumb Screw S760K or Equal mates with 722A PC722A 722RA
146435112.05.0Female Barrel 5.5*2.1*14mm No internal Spring Clip nor Locking Notch or Equal
31123212.05.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
34650012.05.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
161210112.05.0Female Barrel Right Angle, 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
146476112.05.0Female Barrel 5.5*2.1*14mm No internal Spring Clip nor Locking Notch or Equal
144165112.05.0Female Barrel 5.5*2.5*9.0mm, Right Angle WITH internal Spring Clip & Locking Notch or Equal
169738612.05.0Female Barrel 5.5 * 2.5 * 12mm with internal Spring Clip and Locking Notch or Equal
RR9KE5000CCPCIMR6B12.05.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 90
146476212.05.03-Pin Male Cable Connector, Blue, Binder P/N 99-9105-60-03, Serie 720, NO EQUIVALENT!
RR9KE5000LCPCIMR6B12.05.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 35
55641212.05.0Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
146435212.05.0Female Barrel 5.5*2.1*14mm No internal Spring Clip nor Locking Notch or Equal
24946812.05.0Female Barrel 5.5 * 2.5 * 9.5mm with internal Spring Clip and Locking Notch or Equal
157755413.84.34Neutrik NC3FXX-BAG, Female XLR 3 Pin Solder Connector
157795913.84.34Stripped 25+/-5mm, Tinned 8+/-2mm with Black Thermal Contracting Sleeve length 10 +3/-1mm or Equal
RR9KG4000T00CIMR6B15.04.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 152
23902015.04.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
151306415.04.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
163635818.03.33Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
35457518.03.33Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
RR9KH3333T00CIMR6B18.03.33T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 43
88927618.03.33Right Angle Female Barrel 5.5*2.1*14mm w/ Spring Clip & Locking Notch or Equal
89995218.03.33Right Angle Female Barrel 5.5*2.1*14mm w/ Spring Clip & Locking Notch or Equal
RR9KZ3157LCPCIMR6B19.03.15Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal 60
RR9KZ3157T00CIMR6B19.03.15T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 56
24152420.03.0Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
60059020.03.0Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
56820624.02.7Female Barrel 5.5*2.1*9.5mm with internal Spring Clip and Locking Notch or Equal
51429724.02.5Binder# 99-9212-00-04 Female or Equal
50994524.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
RR9KI2500LLWCIMR6B24.02.5Waterproof Female Barrel 5.5 * 2.5 barrel w/thumbscrew; molded equiv to 761KS12, 761KS15, and 761KS17, Insert #451-02180248; mates with L712AS, L712RAS, and PCL712AS 38
56064924.02.5Strip (ROJ) 30mm, Tin (RIJ) 10mm
154404124.02.5ROJ 50 ±5mm, Strip and Tin 9.5 ± 2mm or Equal
91965824.02.5Stripped 25.0 +/- 1mm; Stripped 15.0 +/- 1mm, Tinned 5 +/- 1mm
102435824.02.5Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch or Equal
RR9KI2500T00CIMR6B24.02.5T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 49
26425224.02.5Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
25980524.02.5Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
23828624.02.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
23790024.02.5Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
RR9KI2500CCPCIMR6B24.02.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 50
168431024.02.5T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
164737324.02.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
161208324.02.5Stripped and tinned wires, ROJ: 40.0 +/- 1mm; RIJ: 10.0 +/- 1mm
149152824.02.5DC Power connector, locking, 5.5*2.1mm, 12mm insertion depth; Equiv to S761K & 767K; mates with L722A, PCL722A
159194424.02.5DC Power connector, locking, 5.5*2.1mm, 12mm insertion depth; Equiv to S761K & 767K; mates with L722A, PCL722A
133476324.02.5Stripped 25 +/-5mm; Tinned 9 +/- 2mm or Equal
118572624.02.54-pole, Female Cable Connector, Binder P/N 99 0410 00 04 or equivalent
24960324.02.5Female Barrel Straight , 5.5*2.1*10mm with internal Spring Clip and Locking Notch or Equal
RR9KR2000T00CIMR6B30.02.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 43
41787848.01.25Switchcraft 760 female barrel 5.5*2.5*9.5mm or equivalent Solid Barrel Jack NO Spring Fork
37601348.01.25Switchcraft 760 female barrel 5.5*2.5*9.5mm or equivalent
RR9KX1250T00CIMR6B48.01.25T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 49
22768548.00.8MOLEX P/N:43645-0200 Micro-fit 3.0 (2) circuit connector housing with 2X Molex P/N: 43030-0001 Female terminal or Equal
RR9KS1111T00CIMR6B54.01.11T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit) 57
News Releases
TitleWeb Link

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist ein Steckernetzteil/Tischnetzteil?

Stecker-/Tischnetzteile werden auch als AC-Adapter oder AC/DC-Wandler bezeichnet und sind eine Art externes Netzteil. Diese Geräte können mit einem standardmäßigen IEC 60320-Netzkabel oder mit dem eigenen Eingangssteckersystem als Steckernetzteile verwendet werden und ohne Kabel direkt in die Steckdose gesteckt werden. Einige Elektrogeräte benötigen Strom, es fehlen jedoch die internen Komponenten, um die erforderliche Spannung und Leistung aus dem Stromnetz beziehen zu können. Hier wird ein Netzteil verwendet, das den Wechselstrom in Gleichspannung umwandelt.

Was ist eine Effizienz nach Level VI?

Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.


Ist eine Effizienz nach Level VI erforderlich?

Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.


Was ist die Ökodesign-Richtlinie 2009/125/EG?

Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.

Was ist die EU-Verordnung CoC Tier 2?
Die EU-Verordnung CoC-Tier-2 umfasst eine Reihe von Effizienzzielen für externe Netzteile und AC-Adapter, die von der Abteilung für erneuerbare Energien der GFS (Gemeinsame Forschungsstelle) der Europäischen Kommission veröffentlicht wurden. Es handelt sich um freiwillige Maßnahmen, die gesetzlich nicht vorgeschrieben sind.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?