GTM96600-60VV.V-T3 Desktop/External ICT / ITE / Medical Power Supply/Class 2/Household Power Supply Datasheet

GTM96600-60VV.V-T3 Image
Model ImageGTM96600-60VV.V-T3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C14 AC Inlet Connector,  Class I,  Earth Ground, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: LPS 60950; India BIS; IP41; CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; EAC; South Africa; UL 1310; cETLus 60950-1; cETLus 60601-1-11; CB 62368; UKCA; cETLus 62368-1; NRCan (5V only); Morocco; NOM (5V only); UL 1310; Korea (21.0V-28.0V Only); S-Mark 60950; IRAM; Ukraine; CB 60950; Class I; ETL 60950; CCC; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus 60601-1; cULus ( 5V only); Taiwan BSMI; Korea (6.3V Only); PSE; PSE; PSE; WEEE; VCCI; CE; Level VI; China RoHS; RoHS; FCC; GTM96600-60VV.V-T3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C14 AC Inlet Connector,  Class I,  Earth Ground, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: LPS 60950; India BIS; IP41; CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; EAC; South Africa; UL 1310; cETLus 60950-1; cETLus 60601-1-11; CB 62368; UKCA; cETLus 62368-1; NRCan (5V only); Morocco; NOM (5V only); UL 1310; Korea (21.0V-28.0V Only); S-Mark 60950; IRAM; Ukraine; CB 60950; Class I; ETL 60950; CCC; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus 60601-1; cULus ( 5V only); Taiwan BSMI; Korea (6.3V Only); PSE; PSE; PSE; WEEE; VCCI; CE; Level VI; China RoHS; RoHS; FCC;
Information
Model NumberGTM96600-60VV.V-T3
DescriptionGTM96600-60VV.V-T3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: LPS 60950; India BIS; IP41; CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; EAC; South Africa; UL 1310; cETLus 60950-1; cETLus 60601-1-11; CB 62368; UKCA; cETLus 62368-1; NRCan (5V only); Morocco; NOM (5V only); UL 1310; Korea (21.0V-28.0V Only); S-Mark 60950; IRAM; Ukraine; CB 60950; Class I; ETL 60950; CCC; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus 60601-1; cULus ( 5V only); Taiwan BSMI; Korea (6.3V Only); PSE; PSE; PSE; WEEE; VCCI; CE; Level VI; China RoHS; RoHS; FCC; GTM96600-60VV.V-T3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground, Output Rating: 60 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: LPS 60950; India BIS; IP41; CB 60335; Fuse 60335; 230V CoC Tier 2; ETL; EAC; South Africa; UL 1310; cETLus 60950-1; cETLus 60601-1-11; CB 62368; UKCA; cETLus 62368-1; NRCan (5V only); Morocco; NOM (5V only); UL 1310; Korea (21.0V-28.0V Only); S-Mark 60950; IRAM; Ukraine; CB 60950; Class I; ETL 60950; CCC; RCM; CB 60601-1; S-Mark IEC/EN 60601-1; cETLus 60601-1; cULus ( 5V only); Taiwan BSMI; Korea (6.3V Only); PSE; PSE; PSE; WEEE; VCCI; CE; Level VI; China RoHS; RoHS; FCC;
Agency Documentshttp://www.globtek.info/certs/GTM96600-TZ/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MmCcmEAF
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MmCcmEAF
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MmCcmEAF
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MmCcmEAF
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MmCcmEAF
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000MmCcmEAF
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000MmCcmEAF
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MmCcmEAF
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Externes Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)60
Output Voltage Range (V)5-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP41
Size (mm)117.5*53.5*34.2
Enclosure







User-added image
3D File Downloadhttps://www.globtek.com/dl/GTM96600-T3.igs
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM96600-4005-T3*5840
GTM96600-4005.1-T3*5.17.84340
GTM96600-4005.9-T3*5.96.7739.94
GTM96600-4808-T3*8648
GTM96600-5409-T3*9654
GTM96600-6010-T3*10660
GTM96600-6011-T3*115.4559.95
GTM96600-6012-T3*12560
GTM96600-4812-T3*12448
GTM96600-6013-T3*134.61560
GTM96600-6015-1.2-T3*13.84.3459.89
GTM96600-6014-T3*144.28559.99
GTM96600-6015-T3*15460
GTM96600-6016-T3*163.7560
GTM96600-6017-T3*173.25955.4
GTM96600-6018-T3*183.33359.99
GT-7TD-30-18*181.6730.06
GTM96600-6019-T3*193.1559.85
GTM96600-6020-T3*20360
GTM96600-2424-T3*24124
GTM96600-6024-T3*242.560
GTM96600-6027-T3*272.2259.94
GTM96600-6030-T3*30260
GTM96600-5133.5-T3*33.51.550.25
GTM96600-6035-T3*351.71459.99
GTM96600-6048-T3*481.2560
GTM96600-6054-T3*541.1159.94
GTM96650-6554-T3*541.20364.96
GTM96600-60VV.V-T3-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant) for ≤ 49W rating
<150mW @ 230VAC (EU CoC Tier 2 compliant) for > 49W rating
Inrush Current:30A/60A max. (cold start @ 115V/230VAC)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ 115VAC and full load
Output Regulation:± 5% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector)
Ripple:1% or 100mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation, 1ms typ. recovery time (with 40% to 70% load step)
Hold-up Time:8ms typ. (nominal input voltage and full load)
Power Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Current Protection:110 - 160% of rated output current, auto-restart, current limit range determined by normal output power rating, not de-rated power rating
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 130%, latched off, cycle AC to reset
Over-Temperature Protection:On-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~140°C, latched off, cycle AC to reset

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 85µA max.
Class II F2: 20µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Desktop: C6, C7, C14, or C18 inlet
Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. Removal of LED (cost reduction or aesthetic purpose)
  2. Custom cordsets, various cordage types, and connector types
  3. Custom markings
  4. Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
  5. Reduced leakage current
  6. Tightened output voltage tolerance
  7. Reduced output ripple level
  8. Reduced output power rating
  9. High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
  10. Low temperature option, down to -40°C
  11. Special housing and cordset colors
  12.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  13. Improved ingress protection (IP) rating

Output Connectors

 

 

Derating Curve User-added image
 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)142*62*60
Individual Box/Gift Box Colorwhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.6
Label Width (mm)35.0
Label Height (mm)70.0
Input Configuration
DescriptionIEC 60320/C14 AC Inlet Connector, Class I, Earth GroundUser-added image
Mates with IEC 60320/C13 Plug

Optional Locking IEC60320 Receptable and cord option available on some models by request.:
User-added image

Standard International IEC 320/C13 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

 

Stock Power Supply Cords

Part Number/ LinkCountryPlugTerminationLength (mm)(Ft)
3021457F701(R)N. American (Type B)NEMA 5-15PIEC 320/C1321507
1191068F0701(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C1324598
2194272M5701-T(R)Argentina (Type I)IRAM 2073IEC 320/C1325008
5502022M5701A(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C1325008
204B4272M5701(R)Brazil (Type N)BRAZILIEC 320/C1325008
6023602M5701(R)China (Type I)CCC GR2099IEC 320/C1325008
G8014272M5701(R)Danish (Type K)AFSNIT SECTION 107-2-D1IEC 320/C1325008
23144272M5701-T(R)Europe (Type E)CEE 7/7IEC 320/C1325008
205IN4272M5701(R)               India (Type D)India IS 1293 (also known as IA16A3 or BS546)IEC 320/C1325008
208IN4272M5701(R)India (Type M)India IS 1293 (also known as IA16A3 or BS546)IEC320/C1325008
377C4272M5701(R)Israel (Type H)ISL 377CIEC 320/C1325008
23024272M5701(R)Italy (Type L)CEI 23-16/VIIIEC 320/C1325008
3003339F701(R)
[3x1.25mm2]

3003068F2701-HK(R) 

[3 x 2.0mm2]
Japan (Type B)JIS 8303 / 3 PINSIEC 320/C1325008
302J115J6F0701J(R)Japan / North America (Type B – 12A)JIS 8303 / 3 PINS and NEMA 5-15P (PSE and UL/CUL appr)IEC 320/C1318306
302J104J6F0701J(R)Japan / North America (Type B – 15A)JIS 8303 / 3 PINS and NEMA 5-15P (PSE and UL/CUL appr)IEC 320/C1318306
2313K3432M5701(R)Korea (Type F)KS C 8305IEC 320/C1325008
5804272M5701(R)Russia (Type F)GOST 7396IEC 320/C1325008
2084272M5701(R)South Africa (Type M)South Africa SABS164-1 (16A type)IEC 320/C1325008
23214272M5701(R)Switzerland (Type J)SEV 1011IEC 320/C1325008
3003322M5701(R)Taiwan (Type B)BSMIIEC 320/C1325008
PZ0800100-2M5BK13H(RUK, Hong Kong,Singapore, Gulf States (Type G)BS 1363AIEC 320/C1325008
7055002M5701A(R)InternationalIEC 320 C14-C13IEC 320/C1325008
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageBook 60335 up to 36 Volts
User-added image

 
Taiwan BSMI R32282 GTM96600-3606.3-T3; GTM96600-4005-T3; GTM96600-6012-T3 http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2

No Logo Applicable

CB for IEC 60601-1:2005+A1

No Logo Applicable

CB for IEC 60335-1:2010+A1

No Logo Applicable

CB for IEC 60950-1:2005+A1+A2

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image
仅适用于海拔5000米以下地区使
 
CCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032:2012+AC:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageUL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: eneral Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) ( for 5V only)
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [AAMI ES60601-1:2005 +A1]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision:01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageBureau Of Indian Standards for GTM96600-6012-R3A, GTM96600-4005-R3A,GTM96600-6024-R3A, GTM96600-4005-T3, GTM96600-6012-T3, GTM96600-6015-T3, GTM96600-6019-T3, GTM96600-6024-T3, GTM96600-6048-T3
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE

 
IRAM certificate DC-E-G71-002.9 to IEC 60950-1:2005 + A1:2009 +A2:2013
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageKorea HU10499-17032A (for GTM96600-3606.3-T3 (6.3V)
User-added imageKorea HU10499-20041A for GTM96600-6X24-T3, T3A, R3A (21.0V-28.0V)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source (under 6A) 60950
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageCanadian Energy Efficiency Regulations incorporating amendments 1 (only for model GTM96600-4005 only)
User-added image
 
NOM (Mexico) to NOM-029-ENER-2017 for GTM96600-4005-T3 (5V only)
User-added imageRCM certificate ; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006+A1+A12, EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added image
Serial Number Information
 No LogoSouth Africa approval to SANS IEC 60950
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample RequestDistributor Stock (Click to order)
3588375.08.0Female Barrel 5.5 * 2.1 * 11 mm with internal Spring Clip and Locking Notch or Equal; Barrel rated for 10A
2645335.08.0Female Barrel 5.5*2.5*11.5 mm with internal Spring Clip and Locking Notch or Equal
TR9CB6667T00CIMR6B5.96.77T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)2
TR9CC6000T00CIMR6B7.56.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)37
3250119.06.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
159153512.05.04 Pin Locking Kycon or Equal
34494712.05.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
27147012.05.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
TR9CG4000T00CIMR6B15.04.0T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)37
142209615.04.0Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
23764215.04.0Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
32501418.03.33T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
163635918.03.33Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
TR9CZ3157T00CIMR6B19.03.15T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)30
25931024.02.5Female Barrel 5.5*2.5*11mm, Right Angle with Spring Clip & Locking Notch
35883924.02.5Female Barrel 5.5*2.1*11mm WITH internal Spring Clip and Locking Notch or Equal
TR9CI2500LCPCIMR6B24.02.5Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal51
32501624.02.5T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)
32501848.01.25T-plug system (includes 5.5x2.5, 5.5x2.1, 3.5x1.3mm plugs in each kit)

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Ist für die Stromversorgung über Ethernet (Power over Ethernet) eine Effizienz nach Level VI erforderlich?

Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt.Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt. Im Allgemeinen erfüllen alle Netzteile für die Stromversorgung über Ethernet (PoE) alle Kriterien und müssen eine Effizienz nach Level VI aufweisen.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist eine Effizienz nach Level VI?

Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.


Ist eine Effizienz nach Level VI erforderlich?

Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.


Was ist die Ökodesign-Richtlinie 2009/125/EG?

Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.

Was ist die EU-Verordnung CoC Tier 2?
Die EU-Verordnung CoC-Tier-2 umfasst eine Reihe von Effizienzzielen für externe Netzteile und AC-Adapter, die von der Abteilung für erneuerbare Energien der GFS (Gemeinsame Forschungsstelle) der Europäischen Kommission veröffentlicht wurden. Es handelt sich um freiwillige Maßnahmen, die gesetzlich nicht vorgeschrieben sind.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern

Model

GTD93035L6013.2-F

Ruggedized DC/DC converter, 9-60VDC Input and 60W/13.2VDC output. Alternate output voltages available. IEC 60068 Vibration, Shock, Bump, and Salt Mist tested

GTM96600-60VV.V-T2A

Class II Medical and ITE power supply with IEC60320/C18 input connector provides 60W of output power in a small package

GTM96605-G2-T2
Communication formats supported: USB Power Delivery (PD) 2.0/3.0, Quick Charge™ 2.0/3.0, Quick Charge™ 4.0/4.0+ with up to 7 voltages and VDM options available. Fully globally certified for Medical 60601-1, ICT 62368

Adaptive USB PD Power Supply/ Quick Charge Charger for Medical Grade and ITE/ICT applications for USB PD 2.0 and USB PD 3.0 Applications T2

GT-46600-WWVV-X.X-T3
60 W, DoE Level VI & CoC Tier 2 Efficiency, Three Prong (C14) Inlet, Desktop Adapter, Ac-Dc Power Supply

Level VI Efficiency (EL6)[DOE EPS 2.0] Desktop Power Supply AC Adapter, 60w, output 12-24 VDC

GT-96600-7056-T3-AP

Level VI, DOE EPS 2.0/ErP2 compliant 70W Power over Ethernet (POE) Injector/ PoE HPOE+ PSE (Power Sourcing Equipment), Gigabit, Four Pair, Class I

Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?