GTM96180-18VV-T3A Desktop/External ICT / ITE / Medical Power Supply/Class 2/Household Power Supply Datasheet

Request Information Download PDF Configure Output Connector
GTM96180-18VV-T3A Image
Model Image GTM96180-18VV-T3A, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground  ( aka \
Information
Model NumberGTM96180-18VV-T3A
DescriptionGTM96180-18VV-T3A, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse"), Output Rating: 18 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: IP42; CB 62368; CB 60950; IRAM; Class I; 230V CoC Tier 2; cULus (9V only); EAC; Taiwan BSMI; UKCA; LPS 62368; NrCAN (9V only); UL 1310; ETL 62368; Morocco; cETLus 60601-1 3rd; CE; China RoHS; Level VI; LPS 60950; RoHS; Ukraine; VCCI; WEEE; PSE; PSE; FCC;CAN ICES-3; cETLus; ETL; CB 60601-1; RCM; S-Mark 60950; CCC; CE; CB 60335; cETLus UL1310; Fuse 60335; Fuse 60335;
Agency Documentshttp://www.globtek.info/certs/GTM96180-TZ/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000OjSVYEA3
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000OjSVYEA3
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000OjSVYEA3
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000OjSVYEA3
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000OjSVYEA3
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000OjSVYEA3
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Externes Tischgerät
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)0.6 A
Max Output Power Rating (W)18
Output Voltage Range (V)5-48
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 / Europe Code of Conduct on Energy Efficiency of External Power Supplies - Version 5
Ingress ProtectionIP42
Size (mm)(L)87x(W)47x(H)32mm
EnclosureUser-added image

 
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM96180-1607-2.0-T3A* 53.216
GTM96180-1807-1.05-T3A* 5.95317.85
GTM96180-1811-2.0-T3A* 9218
GTM96180-1817.9-5.9-T3A* 121.518
GTM96180-1817.9-2.9-T3A* 151.218
GTM96180-1830-12.0-T3A* 18118
GTM96180-1830-10.0-T3A* 200.918
GTM96180-1830-6.0-T3A* 240.7518
GTM96180-1830-T3A* 300.618
GTM96180-1848-T3A* 480.37518
GTM96180-18VV-T3A-XXXXCUSTOM CUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       85% rated load current for 85-264VAC
     100% rated load current for 110-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:<75mW @ 230VAC (EU CoC Tier 2 compliant)
Inrush Current:30A/60A maximum, cold start @ 115VAC/230VAC input, respectively
Efficiency:DoE Level VI compliant, EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second max. @ nominal line and full load
Output Regulation± 5% max. (measured at the output connector)
Line Regulation:± 0.5% typ. (measured at the output connector, full load)
Ripple:1% or 100mV, whichever is greater (measured using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Transient Response:5% max. deviation (with 40-70% load step), 1ms typ. recovery time 
Hold-up Time:8ms typ. @ nominal line and full load
Power On Indicator:Green LED

Protections

Input Protection:MOV transient suppressor, input line fusing
Over-Voltage Protection:110-130% of nominal output voltage
Short-Circuit Protection:Auto-restart
Over-Current Protection:110-160% of rated output current (Current limit range is determined by normal output power rating, not derated power level)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 40°C (full load)
See derating table for output power capability at other temperatures.
Extended low temperature range available as a custom option.
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Ingress protection:IP42 standard, IP52 available as a special option
Cooling:Convection
RoHS:Complies with EU 2011/65/EU amended by EU 2015/863 and China SJ/T 11363-2006

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models)
Touch Current:Class I models: < 20uA
Class II models: <75uA
Earth Leakage Current:Class I models: <300uA
Class II models: N/A
Isolation Options:Floating output or Class I earthed output (desktop models)
Earth Continuity Test:< 0.1 ohm between AC inlet earth pin and PCB termination point
Means of Protection:2 x MOPP
Compliant Standards:See listing at the end of this document.

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 8KV contact discharge, 20KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
AC Input Mechanical Options:Wall plug-in, changeable blades (Class II only)
Desktop housing, extended housing: C6, C8, C14, or C18 IEC inlet (Class I or Class II)
Markings:Label or laser printed
 

Special Options

  1. Removal of LED (optional)
  2. Custom cord-sets (custom cord and/or connector types). Note: 5VDC USB power supplies with Micro-B or Type-C connectors have a voltage regulation specification of ±8% (4.6V to 5.4V).
  3. Custom markings
  4. Short term output surge capability
  5. Reduced leakage current versions (10uA max) for Type-CF medical applications and/or for AC noise sensitive equipment. (15W or less, 5 to 24V output voltage range.)
  6. Tightened output voltage tolerance
  7. Reduced output voltage ripple
  8. Improved reliability PCB laminate with plated-through-holes for IPC610 Class 2 compliance
  9. Custom housing colors
  10. Quasi constant-current output for SLA (lead-acid) battery charging applications
Derating Curve
User-added image

 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)480 x 450 x 205
Gross Weight (kg)15.2
Label Width (mm)36.5
Label Height (mm)48.5
Input Configuration
DescriptionIEC 60320/C6 AC Inlet Connector, Class I, Earth Ground ( aka "Mickey Mouse")User-added image

Mates with IEC 60320/C5 Plug

 
 Standard International IEC 320/C5 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material. 

Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)
3021066F712(R)N. American (Type B)NEMA 5-15PIEC 320/C518806
1191068F0712(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C524598
2194262M0712(R)Argentina (Type I)IRAM 2073IEC320/C520506.7
2064262M0712(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C520006.6
204B4262M0712(R)Brazil (Type N)BRAZILIEC 320/C520006.6
6023592M5712(R)China (Type I)CCC GR2099IEC 320/C525008
23144262M0712(R)Europe (Type E)CEE 7/7IEC 320/C520506.6
2313K3432M0712(R)Korea (Type F)KS C 8305IEC 320/C520006.6
205IN4262M0712(R)India (Type D)India IS 1293 (also known
as IA16A3 or BS546)
IEC320/C520006.6
377C4262M0712(R)Israel (Type H)ISLIEC320/C520506.7
23024262M0712(R)Italy (Type L)CEI 23-16/VIIIEC 320/C520006.6
3003316F0712(R)Japan (Type B)JIS 8303 / 3 PINSIEC 320/C518306
3021066F0712ULPSE(R)Japan / USA (Type B)JIS 8303 / 3 PINS +
NEMA 5-15P
IEC 320/C518306
2054262M0712(R)S. Africa (Type D)South Africa SABS164-1   (6A type plug)IEC320/C520506.7
2084262M0712(R)S.Africa (Type M)South Africa SABS164-1 (16A type plug)IEC 320/C520006.6
23214262M0712(R)Switzerland (Type J)SEV 1011 ( EL 203)IEC 320/C520006.6
3003316F0712(R)Taiwan (Type B)BSMIIEC 320/C520006.6
6104262M0712(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C520006.6
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo ApplicableEU 230V CoC Tier 2, 278/2009, Mar 2014
User-added imageBook 60335 up to 36 Volts
 User-added imageBSMI Taiwan GTM96180-18VV-T3(A) (5V, 6V, 7.5, 9V, 12, 15V, 18, 19V, 20V, 24V, 30, 48V) CN13438, CN14336 http://www.bsmi.gov.tw/wSite/ct?xItem=4072&ctNode=816&mp=2

No Logo Applicable

IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1)

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
 User-added imageCCC to GB4943. 1-2011; GB9254-2008; GB17625. 1-2012 with Tropical and Altitude up to 5000 m approval.

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added imageAudio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements (UL 60950-1 Issued: 2007/03/27, Ed: 2 Rev: 2014/10/14) Information Technology Equipment Safety Part 1: General Requirements (CSA C22.2 No. 60950-1 Issued: 2007/03/27 Ed: 2 (R2012) Amd.
User-added imageConforms to ANSI/UL Std. 60950-1 2nd Edition Cert. to CAN/CSA Std.C22.2 NO.60950-1 2nd Edition
User-added image
Class 2 Power Unit
 
cETLus-Cert 4007497 UL1310 Recognized Component up to 36 volts
User-added image
 
AAMI ES60601-1 Issued: 2012/08/20 Medical Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11:
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imageUL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) 9V only
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageEnergy verified for GTM96180-1811-2.0-T3A
User-added imageCompliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.
User-added imageFuse 60335 T1.6A 250VAC Up to 36 volts
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE

 
IRAM certificate DC-E-G71-002.8 to IEC 60950-1:2005 + A1:2009 +A2:2013
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561.pdf, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V?30V]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50471561, to J62368-1(H30) , J55032(H29), J3000(H25) ,[15V or less]. Please reference the following website for PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
User-added imageNatural Resources Canada (NRCan): CSA Standard C381.1-08, QSP NRCAN EEV1191; http://shop.csa.ca/en/canada/energy-efficiency/cancsa-c3811-08/invt/27024802008
User-added image
 
RCM certificate SAA-161679-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageS-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageUL1310 Warning Label Up To 36 Volts with plugs
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
125910812.01.5Female Barrel 5.5 * 2.1 * 13.8 mm w/ 6.5mm Thumb Screw S760K or Equal mates with 722A PC722A 722RA
27415115.01.2Female Barrel EIAJ4 5.5*3.3*11mm w/1.0 mm Pin, internal Spring Clip, and Locking Notch or Equal
28492715.01.2Female Barrel 5.5*2.5*11mm, with internal spring clip and locking notch
34379324.00.8Stripped 20+/-2mm, Tinned 5+/-2mm with Black Thermal Contracting Sleeve or Equal
26641048.00.375Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
News Releases
TitleWeb Link

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Ist für die Stromversorgung über Ethernet (Power over Ethernet) eine Effizienz nach Level VI erforderlich?

Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt.Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt. Im Allgemeinen erfüllen alle Netzteile für die Stromversorgung über Ethernet (PoE) alle Kriterien und müssen eine Effizienz nach Level VI aufweisen.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

Was ist eine Effizienz nach Level VI?

Die Stufen I bis VI sind Teil eines internationales Protokolls zur Effizienzkennzeichnung, mit dem Hersteller die Effizienz eines Produkts bestimmen können. Diese Leistung basiert auf der Messung der Effizienz im aktiven Modus und der Leistung im Leerlaufmodus von externen Netzteilen oder AC/DC-Adaptern, die bei verschiedenen Ausgangsleistungen getestet werden. Die Leistung im Leerlaufmodus bezieht sich auf den Stromverbrauch, den ein externes Netzteil auch dann aufweist, wenn die Anwendung ausgeschaltet oder getrennt wird.


Ist eine Effizienz nach Level VI erforderlich?

Eine Effizienz nach Level VI ist in bestimmten Ländern und Regionen für bestimmte Produkte oder bestimmte Anwendungen vorgeschrieben.


Was ist die Ökodesign-Richtlinie 2009/125/EG?

Mit der Ökodesign-Richtlinie wurden in Europa die neuesten Anforderungen an Energieeffizienz und Energieeinsparung für AC/DC-Adapter und externe Netzteile erlassen.

Was ist die EU-Verordnung CoC Tier 2?
Die EU-Verordnung CoC-Tier-2 umfasst eine Reihe von Effizienzzielen für externe Netzteile und AC-Adapter, die von der Abteilung für erneuerbare Energien der GFS (Gemeinsame Forschungsstelle) der Europäischen Kommission veröffentlicht wurden. Es handelt sich um freiwillige Maßnahmen, die gesetzlich nicht vorgeschrieben sind.

Wie funktioniert ein AC/DC-Adapter?

Der AC/DC-Adapter oder das externe Netzteil besteht aus einem Netzteil, das in einem Gehäuse verbaut und zum Anschluss an das Wechselstromnetz mit einem Stecker versehen ist. Deshalb wird häufig auch von einem Steckernetzteil gesprochen. Das Netzteil wird in die Steckdose gesteckt und die Wechselspannung wird dann vom AC/DC-Adapter in eine Gleichspannung umgewandelt, die über das angeschlossene Ausgangskabel in das zu versorgende Gerät eingespeist wird.

Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?