GTD9X1003-WWWVV-TW Desktop/External ICT / ITE / Medical Power Supply/Class 2/Household Power Supply Datasheet

GTD9X1003-WWWVV-TW
GTD9X1003-WWWVV-TW, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 12-36V, , Output Rating: 100 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: China RoHS; Double Insulation; PSE; RoHS; UKCA; Ukraine; VCCI; WEEE; GTD9X1003-WWWVV-TW, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply,  60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 12-36V, , Output Rating: 100 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: China RoHS; Double Insulation; PSE; RoHS; UKCA; Ukraine; VCCI; WEEE;GTD9X1003-WWWVV-TW, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 12-36V, , Output Rating: 100 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: China RoHS; Double Insulation; PSE; RoHS; UKCA; Ukraine; VCCI; WEEE; GTD9X1003-WWWVV-TW, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Desktop/External, DC-DC, , Input Rating: 12-36V, , Output Rating: 100 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: China RoHS; Double Insulation; PSE; RoHS; UKCA; Ukraine; VCCI; WEEE;
Information
Model NumberGTD9X1003-WWWVV-TW
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MvtUoEAJ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MvtUoEAJ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MvtUoEAJ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MvtUoEAJ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000MvtUoEAJ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000MvtUoEAJ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External / Externes Tischgerät
TechnologyDC-DC
CategoryICT / ITE / Medical Power Supply/Class 2/Household Power Supply / ICT / ITE / Medical Power Supply/Class 2/Household Power Supply
Input Voltage Range (V)12-36V
Max Input Current (A)12.0A
Max Output Power Rating (W)100
Output Voltage Range (V)12-54
Efficiency
Ingress ProtectionIP43
Size (mm)149.4 x 62.6 x 33.5
Enclosure




User-added image

 
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTD9X1003-10019-TW*195.263100
GTD9X1003-10028-TW*283.57199.99
GTD9X1003-10022-TW*224.54599.99
GTD9X1003-10018-TW*185.5599.9
GTD9X1003-10036-TW*362.7799.72
GTD9X1003-10024-TW*244.1699.84
GTD9X1003-10015-TW*156.66699.99
GTD9X1003-6015-TW*15460
GTD9X1003-10012-TW*128.3399.96
GTD9X1003-10048-TW*482.0899.84
GTD9X1003-10030-TW*303.3399.9
GTD9X1003-10054-TW*541.8599.9
GTD9X1003-WWWVV-TW-XXXXCUSTOMCUSTOMCUSTOM
* (Final ordering #/Part No to be defined)
Specifications

 

Features

  • 2 x MOPP medical isolation
  • EMS-ready per IEC60601-1-12
  • Wide "universal" DC input range
  • 120W short-term power capability (optional)
  • Shock & vibration in accordance with IEC60601-1-12 (EMS)

Input

Input Voltage Range:12 - 36VDC (nameplate, nominal)
10.2 - 39.6VDC (rated, -15% / +10%)

Plus short-term capability between 9.0 - 10.2V. (Duration is limited by temperature rise.)
Input Current:9.5A (typ.) @ 12VDC
12.0A (max.) @ 10.2VDC
No Load Input Power:< 0.5W
Efficiency:87% @ 12VDC, 90% @ 24VDC typ., at a "typical" 60W usage scenario

Output

Turn-on Delay:< 2 seconds
Output Regulation:+1.5% / -4% max. (measured at the output connector)
Line Regulation:± 0.1 % typ.  (measured at the output connector)
Ripple:1% max. (using a 10µF low-ESR electrolytic cap + 0.1µF ceramic cap, measured @ 20MHz BW, at the output connector)
Transient Response (Step Load):10% max. deviation, 2ms max. recovery time (with 100W load step)
Transient Response
(Load Dump):
5% max. deviation, 100ms max. recovery time (with 100W load dump)

Protections

Input Protection:Input line fusing (high-breaking capacity)
Reverse polarity protection (up to -36VDC)
Input Under-Voltage Protection:Shut down @ 7.4V (typ.), Restore @ 9.0V (max.)
Output Over-Voltage Protection:110 - 130%, Latching, cycle DC input voltage to reset
Output Over-Current Protection:110 - 150%, Auto-recovery
Output Short-Circuit Protection:Auto-recovery
Over-Temperature Protection:Latching, cycle DC input voltage to reset

Environmental

MTBF:> 1,500,000 hours @ 25°C ambient (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (100W)
Check derating curve for T > 40°C.
Storage Temperature:-40°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude5000m
Cooling:Natural convection
Shock:End use handling: Half-sine, <3ms duration, 1.65m/s, 3 shocks per face
Transportation simulation: Trapezoid, 60G acceleration, 5.75m/sec, 3 shocks per face
General shock: Half-sine, 100G acceleration, 6ms duration, 3 shocks per face
Vibration:IEC60601-1-12, Section 10.1.3, Clause B
Bump:EN1789, Clause 6.4.1
Drop:EN1789, Clause 6.4.2
Ingress Protection:IP43
RoHS:Complies with EU 2015/863 and China SJ/T 11363-2006

Safety

Compliant Standards:General medical: IEC60601-1
Emergency medical services (EMS): IEC60601-1-12
Information & communications technologies (ICT): IEC62368-1
Dielectric Withstand Voltage (Hi-Pot):4300VDC from input to output,  1 minute
4300VDC from input to case, 1 minute
500VAC from output to case, 1 minute
Output Leakage Current:NC: 8µA max.
SFC: 40µA max.
Means of Protection (Primary-to-Secondary):2 x MOPP
Protection Class:Class II (reinforced insulation)

EMC

Compliant Standards:Medical: IEC60601-1-2
Aftermarket automotive: EN50498
Conducted Emissions:CISPR25, Class 3
(measured with resistive load)
Radiated Emissions:CISPR25, Class 3
EN50498
(measured with resistive load)
Electrical Transient Conduction Along Supply Lines:ISO7637-2 (Test conditions for  12V nom.  / 24V nom. systems, respectively)
   Test Pulse 1:  - 100V / -600V (5,000 pulses)
   Test Pulse 2a: + 50V / + 50V (5,000 pulses)
   Test Pulse 2b: + 10V / + 20V (10 pulses)
   Test Pulse 3a: -150V / - 200V (1 hour)
   Test Pulse 3b: +100V / + 200V (1 hour)
   Test Pulse 4: -6V / -12V (1 pulse)

ISO16750-2 Load Dump:
   12V nom. system: Test Pulse B : Us* = 35V, Ri = 2Ω, td = 400ms
   24V nom. system: Test Pulse B:  Us* = 65V, Ri = 2Ω, td = 350ms
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge, Criterion A
Radiated RF Immunity:EN61000-4-3, 20V/m @ 80MHz - 2.7GHz, 80% 1KHz AM, 80% 5Hz AM, Criterion A
Conducted RF Immunity:EN61000-4-6, 3VRMS & 6VRMS (ISM & Amateur bands), 80% 1KHz AM, Criterion A

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Markings:Adhesive backed label or laser engraving
Derating CurveUser-added image
 
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)480 x 450 x 205
Gross Weight (kg)15.2
Label Width (mm)50.0
Label Height (mm)110.0
Input Configuration
Description
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
UKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
248948730.03.33
248952436.02.77
248983324.04.16
248958754.01.85
248981012.08.33
240713618.05.55
248957148.02.08

Was ist ein AC-Adapter nach IEC 60601-1 für die Medizintechnik?

Ein AC-Adapter nach IEC 60601-1-2 für die Medizintechnik wandelt die aus der Steckdose bezogene Eingangsspannung in eine niedrigere Spannung (in der Regel Gleichstrom) um, die zum Betrieb von medizinischen Geräten verwendet wird. AC-Adapter nach IEC 60601-1-2 für die Medizintechnik sind normalerweise in einem Kunststoffgehäuse verbaut und mit 2-poligen oder 3-poligen Eingangssteckern erhältlich. Netzteile sind auch als Open-Frame-Netzteil zum Einbau in Medizinprodukte verfügbar. Diese AC/DC-Wandler sind in Übereinstimmung mit internationalen medizinischen Standards konzipiert und gewährleisten die Einhaltung bestimmter Aspekte, was sie von herkömmlichen Netzteilen für Geräte der Informations- und Kommunikationstechnik unterscheidet.


Warum ist mein Netzteil nach IEC 60601-1 für die Medizintechnik nach IEC 60601-1 (3. Ausgabe) zertifiziert, während der neueste Standard IEC 60601-1 (4. Ausgabe) ist?

IEC 60601-1 umfasst verschiedene Abschnitte mit Spezifikationen für Sicherheit und EMI/EMV. Die neueste Version des Sicherheitsabschnitts von IEC 60601-1 ist die 3. Ausgabe, während hinsichtlich EMI/EMV die neueste Version 60601-1-2 (4. Ausgabe) ist. Wann ist 60601-1-2 (4. Ausgabe) in Kraft getreten? 60601-1-2 (4. Ausgabe) ist am 31. Dezember 2018 in Kraft getreten.


Was ist der Unterschied zwischen einem Netzteil für die Medizintechnik nach IEC 60950-1 und IEC 60601-1?

Die Netzteile nach IEC 60950-1 und IEC 60601-1-2 sind beide AC/DC-Wandler und können entweder extern oder als Modelle zum Einbau eingesetzt werden. Sie sind jedoch für unterschiedliche Spezifikationen ausgelegt, um den -Anforderungen des Endsystems zu entsprechen. Während die grundlegenden Leistungsmerkmale ähnlich sind, wie z. B. Eingangs- und Ausgangsspannungen und mechanische Eigenschaften, gibt es auch viele Unterschiede. Einige der Hauptunterschiede bestehen darin, dass AC/DC-Adapter nach IEC 60601 für die Medizintechnik eine höhere dielektrische Spannungsfestigkeit und einen niedrigeren Ableitstrom aufweisen müssen. Abhängig von der Endanwendung sind viele andere Unterschiede und Aspekte zu berücksichtigen. Was ist MOOP und MOPP? Medizinprodukte müssen eine oder mehrere Schutzmaßnahmen (MOPs = Means of Protection) aufweisen, um Patienten und Bediener vor den Risiken eines Stromschlags zu schützen. Eine Schutzmaßnahme (MOP) kann eine galvanische Trennung, eine Schutzerdung, eine definierte Kriechstrecke oder eine Luftstrecke oder eine andere Schutzimpedanz sein. Diese können in verschiedenen Kombinationen verwendet werden. Die 3. Ausgabe der IEC 60601-1 unterscheidet zwischen dem Risiko für Patienten und dem Risiko für Bediener. Ein MOP kann daher als Maßnahme zum Patientenschutz (MOPP = Means of Patient Protection) oder als Maßnahme zum Anwenderschutz (MOOP = Means of Operator Protection) klassifiziert werden. Der Hauptunterschied zwischen einer MOOP und einer MOPP besteht hauptsächlich in der zulässigen Kriechstrecke. Beide Anforderungen werden mit einer Basisisolierung erfüllt. Für eine 2 x MOPP-Zertifizierung ist die Isolationsprüfung bei 4000 VAC besonders anspruchsvoll und die Kriechstrecke von 8 mm ist doppelt so lang wie die für eine MOPP erforderliche.


Was ist ein Typ-BF- und Typ-CF-zertifizierter AC-Adapter für die Medizintechnik nach IEC 60601-1-2 und wo liegt der Unterschied?

Netzteile und AC/DC-Adapter für die Medizintechnik werden abhängig der Anwendungsteile in eine von drei Klassen eingeteilt: Typ B (Body = Körperbezug), Typ BF (Body Floating = Körperbezug mit Stromfluss) und Typ CF (Cardial Floating = Herzbezug mit Stromfluss). Diese Anwendungsteile erfordern bestimmte Merkmale wie Isolationsspannung, Kriechspannung und Ableitstrom. Stromfluss (Floating) bezieht sich auf ein nicht geerdetes Netzteil (Klasse II), bei dem keine Verbindung zu einem anderen Ausgang besteht und das vollständig isoliert ist. Typ B bezieht sich auf Geräte, die in der Nähe des Patienten zum Einsatz kommen, gemäß IEC 60601-1 in einem Umkreis von 1,5 m vom Stuhl oder Bett eines Patienten, keinen Strom auf die Patienten übertragen und geerdet sind. Zu diesen Geräten gehören OP-Leuchten, Krankenhauswagen und -betten, automatisierte Spender für Medikamente und Verbrauchsmaterialien sowie Diagnosegeräte wie Röntgengeräte. Geräte vom Typ BF liefern elektrische Energiesignale an oder von dem Patienten, wie z. B. elektrochirurgische Geräte, Endoskope und elektrische Patientenmonitore wie Thermometer. Bei Geräten vom Typ CF verhält es sich ähnlich wie bei Typ BF, mit der Ausnahme, dass sie Geräte mit Strom versorgen, die mit dem Herzen verbunden sind, wie Defibrillatoren, externe Herzschrittmacher oder Elektrodenkatheter (EKG). Typ CF erfordert einen höheren Schutz gegen elektrischen Schlag als Geräte des Typs BF.

Ist für die Stromversorgung über Ethernet (Power over Ethernet) eine Effizienz nach Level VI erforderlich?

Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt.Nach Angaben des Energieministeriums der Vereinigten Staaten von Amerika kann ein EPS (External Power Supply = externes Netzteil) als EPS der Klasse A angesehen werden, wenn es über eine elektrische Verbindung, ein Kabel, eine Leitung oder eine andere Verkabelung, einschließlich steckbarer und fester Kabel, an die Endanwendung angeschlossen wird. Ein Ethernet-Kabel würde diese Kriterien erfüllen, sodass ein EPS, das über ein Ethernet-Kabel mit dem Endprodukt verbunden ist, weiterhin als EPS der Klasse A betrachtet wird und den geltenden Energieeinsparungsstandards unterliegt, wenn es die anderen fünf Kriterien für ein EPS der Klasse A erfüllt. Im Allgemeinen erfüllen alle Netzteile für die Stromversorgung über Ethernet (PoE) alle Kriterien und müssen eine Effizienz nach Level VI aufweisen.

Was ist ein Netzteil nach IEC 62368-1:2018?

Die IEC 62368-1: 2018 gilt für die Sicherheit elektrischer und elektronischer Geräte im Bereich der Audio-, Video-, Informations- und Kommunikationstechnik sowie für den Geschäfts- und Bürobereich mit Nennspannungen von bis zu 600 V. Es handelt sich um einen Produktsicherheitsstandard, der Energiequellen klassifiziert, Schutzmaßnahmen hinsichtlich dieser Energiequellen vorschreibt und Leitlinien für die Anwendung dieser Schutzmaßnahmen sowie die Anforderungen daran darlegt. Die vorgeschriebenen Schutzmaßnahmen sollen die Wahrscheinlichkeit des Auftretens von Schmerz, Verletzungen und Sachschäden im Brandfall verringern. Ein AC/DC-Wandler oder Netzteil nach IEC 62368-1 ist ein Netzteil, das nach dieser Norm geprüft und zertifiziert wurde.


Haben IEC 62368-1-Netzteile die IEC60950-1-Netzteile abgelöst?

Ab dem 20. Dezember 2020 werden die Sicherheitsstandards IEC 60065 und IEC 60950-1, die bislang für Geräte der Informations-, Audio- und Videotechnik galten, von IEC 62368-1 abgelöst. In Nordamerika gelten die ETL- und UL 60950-1-Zertifizierungen weiterhin und können bis auf Weiteres weiterhin verwendet werden.


Was ist der Unterschied zwischen einem Netzteil nach IEC 62368-1 und IEC 60950-1?

Während die Struktur und der Inhalt der Normen im Allgemeinen sehr unterschiedlich sind, entsprechen die meisten Produkte, die zuvor der IEC 60950-1 entsprachen, der neuesten Norm IEC 62368-1 und es sind keine oder nur geringe Änderungen erforderlich.


Ist mein Netzteil nach IEC60950-1 weiterhin verfügbar?

GlobTek wird die Netzteile nach IEC 60950-1 bis auf weiteres auf unbestimmte Zeit herstellen und liefern.

What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI).
Information anfordern
Call
Email
💬
Text
💁
Chat
?
Angebotsanfrage
Können wir Ihnen helfen?
Können wir Ihnen helfen?